Table 1 - Performance and Dimensional Data - Tubular 30 thru 120 Propeller Unit Heater

Unit

Size

30 45 60 75 90 105

120

PERFORMANCE DATA†

Input

-

BTU/Hr.

30,000 45,000 60,000 75,000 90,000 105,000

120,000

(kW)

(8.8)

(13.2)

(17.6)

(22.0)

(26.4)

(30.8)

(34.2)

Output

-

BTU/Hr.

24,300 36,450 48,600 60,750 72,900 85,050 97,200

(kW)

(7.1)

(10.7)

(14.2)

(17.8)

(21.4)

(24.9)

(28.5)

Thermal

Effi

ciency

(%)

81 81 81 81 81 81 81

Free Air Delivery - CFM

370

550

740

920

1,100

1,300

1,475

(cu. m/s)

(.175)

(.260)

(.349)

(.434)

(.519)

(.614)

(.696)

Air

Temperature

Rise

-

Deg.

F

60 60 60 60 60 60 60

(Deg. C)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

Full

Load

Amps

at

120V

3.0 3.0 3.7 4.1 6.4 6.4 6.4

Maximum

Circuit

Ampacity

3.5 3.5 4.4 4.8 7.5 7.5 7.5

MOTOR DATA: Motor HP

1/20

1/20 1/12 1/12 1/10 1/10 1/10

Motor

(kW)

(0.04) (0.04) (0.06) (0.06) (0.075)

(0.075)

(0.075)

Motor

Type

SP SP SP SP SP SP SP

R.P.M.

1650 1650 1050 1050 1050 1050 1050

Motor

Amps

@

115V

1.9 1.9 2.6 2.6 4.2 4.2 4.2

DIMENSIONAL DATA - inches (mm)

“A”

Jacket

Height

12-3/8 12-3/8 15-7/8 15-7/8 22-5/8 22-5/8 22-5/8

(314) (314) (403) (403) (574) (574) (574)

“B” Overall Height

13-1/4

13-1/4

16-13/16

16-13/16

23-9/16

23-9/16

23-9/16

(337) (337) (427) (427) (598) (598) (598)

“C”

Overall

Depth

25-7/8 25-7/8 26-3/16

26-3/16 26-3/8 26-3/8 26-3/8

(632) (632) (665) (665) (670) (670) (670)

“D1” Center Line Height of Flue*

8-1/2

8-1/2

10-3/8

10-3/8

13-5/8

13-5/8

13-5/8

(216) (216) (263) (263) (346) (346) (346)

“D2” Center Line Height of Air Intake

8-1/2

8-1/2

8

8

8-5/8

8-5/8

8-5/8

(216) (216) (203) (203) (219) (219) (219)

“E”

Fan

Diameter

10 10 14 14 16 16 16

(254) (254) (356) (356) (406) (406) (406)

“F” Discharge Opening Height

10-13/16

10-13/16

14-7/16

14-7/16

21-3/16

21-3/16

21-3/16

(275) (275) (367) (367) (538) (538) (538)

“G”

Vent

Connection

Diameter

4 4 4 4 4 4 4

(102) (102) (102) (102) (102) (102) (102)

“H1” Center Line of Flue Connection From Side

7-1/4

7-1/4

7-1/4

7-1/4

7-3/4

7-3/4

7-3/4

(184) (184) (184) (184) (197) (197) (197)

“H2” Center Line of Air Intake From Side

2-3/4

2-3/4

2-3/4

2-3/4

3-1/2

3-1/2

3-1/2

(70) (70) (70) (70) (89) (89) (89)

Vent Size Requirements - Standard Combustion
Category I Horizontal**

4

4

4

5

5

5

5

(102) (102) (102) (127) (127) (127) (127)

Category III Horizontal

4

4

4

4

4

4

4

(102) (102) (102) (102) (102) (102) (102)

Category I & III Vertical

4

4

4

4

4

4

4

(102) (102) (102) (102) (102) (102) (102)

Vent Size Requirements - Separated Combustion
Exhaust Diameter**

4

4

4

4

5

5

5

(102) (102) (102) (102) (127) (127) (127)

Intake Air Diameter

4

4

4

4

5

5

5

(102) (102) (102) (102) (127) (127) (127)

Unit

Weight

-

lbs.

57 60 75 87 96 103

112

(kgs)

(27)

(29)

(34)

(37)

(45)

(48)

(49)

Shipping

Weight

-

lbs.

67 70 90 96 109

143

152

(kgs)

(32)

(33)

(41)

(44)

(51)

(66)

(67)

* For all installations, the fl ue collar is included with the unit and should be fi eld installed per the instructions included with the unit.
** 4-5" reducer supplied where required.
† Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 610m). For unit installations in U.S.A. above 2,000 ft. (610m), the unit input must be derated 4% for each 1,000 ft. (305m) above sea

level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223.1 (N.F.P.A. No. 54), (also refer to Table 6).