HOUSING REPLACEMENT
Removal

1. Remove the chuck as described above.
2. Remove the top housing half and gearbox as de-

scribed above.

3. Remove the armature from the tool.
4. Remove the field as described above
5. Remove the switch as described above.
6. Remove the power cord from the tool. It should just

pull out of the wire channel.

7. Disconnect the red brush lead from the brush holder

in the left housing half and remove the switch wiring

harness. Like the power cord, this should pull right

out.

8. Press the brush holders out of each housing half.

Installation

1. Install a service warning label on the new housing.

The service warning label is only partially laminated.

Half of the label has a backing on the lamination that

can be peeled off allowing the technician to write on

the label and finish laminating it him/herself. Record

the tool serial number with a pen on the label, peel the

backing off of the lamination, and laminate the

service warning label.

2. Install new decorative and brand labels if desired.
3. The remainder of assembly is the reverse of the

removal instruction above.

WIRE ROUTING / REPLACEMENT

As noted in the above sections, it is very important to note

the routing of the wires before disassembly. They must be

routed exactly the same way upon assembly. Some

additional detail on proper wiring follows.
It is very easy to pinch a wire when reassembling a tool if

care is not given to wire routing. Take note of which ribs

contact the switch and field, and where wires must be

routed to clear them. The bundle of 4 switch wires must be

placed with 2 of the wires in each of the 2 wire slots

provided as the wires pass under the motor coupling.

One of the wires from the power cord must be placed in on

top of each bundle of switch wires and pressed firmly into

place. This will hold the wires down and away from the

motor coupling.

As an aid to reassembly, take note of wire routing

and position in wire guides and traps while dis-

mantling tool.

White wire #5 is to be routed around the lower brush boss

between the boss and the field.
Yellow wire #7 must pass under the power cord wire and

exit between the cord strain relief and the screw boss. This

allows enough slack to attach the wire to the upper brush

holder while lowering the housing.