4. The

MaxiMixer has also been supplied to you with a complete scale system. Read and

understand the scale manual and familiarize yourself with its different functions. The scale
indicator needs to be connected to a power source. Connect the scale indicators power cord
directly to the solenoid operated hydraulic valve (if so equipped) or to the battery either on the
mixer or the tractor. The leads are supplied with 1 white wire and 1 black wire. The white wire
is to be connected to the positive and the black is to be connected to the ground. By having the
scale connected to a constant power source, it will save warm up time between feedings. It is
recommended to run the scale wires separately from other power lines to keep electrical
interference to a minimum. A 10 amp inline fuse also protects the scale indicator.

IMPORTANT! ALWAYS DISCONNECT SCALE LEADS BEFORE PERFORMING
ANY SERVICE WORK SUCH AS WELDING!

DANGER!

TO PREVENT SERIOUS INJURY OR DEATH, TURN

OFF PTO, TURN OFF ENGINE AND PULL THE KEY, SET

PARKING BRAKE, AND WAIT FOR ALL MOTION TO STOP
BEFORE ADJUSTING PTO LENGTH AND WORKING ON THE

DRAWBAR.