12 electromagnetic immunity, Electromagnetic immunity – Seagate MOMENTUS ST9100826A User Manual

Page 21

Advertising
background image

Momentus 5400 FDE Product Manual, Rev. C

15

2.12

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.

2) No data loss.

B - 1) Unit self recovers without user intervention.

2) No data loss.

C - 1) Upset OK provided that unit will function after user intervention.

Table 5:

Electromagnetic immunity

Test

Description

Performance

level

Reference

standard

Electrostatic discharge

Contact, HCP, VCP: ± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz
sine

A

EN 61000-4-6: 97

Power Frequency H-field
immunity

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

Voltage dips, interrupts

30% Reduction for 25 cycles

>95% Reduction for 250 cycles

>95%, 0.5 cycles

C

C

B

EN 61000-4-11: 94

Advertising
This manual is related to the following products: