Wiring, Circuit breakers and fuses, Human reign amplifier fuse values – Soundstream Technologies HR 4 User Manual

Page 13

Advertising
background image

WIRING

POWER AND GROUND
To ensure maximum output from your Human Reign amplifier, use high quality,
low-loss power and ground cables and connections. The Human Reign
amplifiers will accept up to 2 gauge power and ground cables. Determine from
the chart below the minimum gauge power and ground wire for your application.

13

up to 10´

up to 20´

HR 2

HR 4

2 or 4 gauge

2 gauge only

CIRCUIT BREAKERS AND FUSES

EXTERNAL
Like all audio components, the Human Reign amplifier must be fused near the
battery. A fuse or circuit breaker must be located within 18” of the battery. This
will prevent a fire in the event of a shorted cable. See the chart below to
determine the correct fuse value.

INTERNAL
The Human Reign amplifiers are fused with an automotive-type or Maxi-fuse. In
the event of a blown power supply fuse(s), replace with the correct value fuse
found in the chart below. Never replace the fuse with a higher value than what
is supplied. This may result in amplifier damage and will void the warranty!

Human Reign Amplifier Fuse Values

Battery Fuse / Circuit Breaker

200 amp

2 or 4 gauge

2 gauge only

140 amp

HR 2

HR 4

Advertising