Superior UNVENTED GAS LOG ROOM HEATERS VFGL-28VSP-4 SERIES User Manual

Page 5

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

5

Noncombustible Material Requirements with No Mantel Installed

(A) Noncombustible Material Measurement

Requirements for Safe Installation

12" or more

Adjustable canopy not required.

8" minimum to 12"

Install adjustable canopy, P/N 053752
(

Figure 3 ).

Less than 8"

Extend noncombustible material to at least
8" and install adjustable canopy (

Figure 3 ).

or
Extend noncombustible material to a height
of at least 12".

Table 2

Noncombustible Material Heights and Mantel Location

Requirements for Safe Installation

with Wood Mantel, Shelf or

Noncombustible Material Measurement

Other Combustible Projection

12" or more

Adjustable canopy not required. Observe pro-
files shown in

Figure 4.

8" minimum to 12"

Install adjustable canopy and observe pro-
files shown in

Figure 5.

or

Extend heat resistant material to at least 12"
and observe profiles shown in

Figure 4.

Table 3

8" or More of

Noncombustible

Material

Heater in Fireplace

or Firebox

Adjustable

Canopy

Step 4. Wood mantel, shelf or combustible
projection requirements:
To install a wood
mantel, shelf or other combustible projection
directly above the fireplace (firebox), refer to
Table 3 and to Figures 4 and 5 for installation
profiles.

If your mantel profile is unsafe, you may either:

Raise the mantel to an acceptable height, or

Remove the mantel.

Example: The bottom of the mantel may project
from the wall a maximum of 2-1/2" at a mini-
mum of 28" above the opening. The top shelf of
the mantel may project a maximum of 6" at a
minimum of 34-1/2" above the opening.

Figure 4

Figure 3

Step 3. Noncombustible materials (minimum
requirements):
To install the room heater with-
out wood mantels, shelves or other combus-
tible projections directly above the opening of
the fireplace (firebox) refer to

Figure 2 and

Table 2. Note that at least 8" of noncombustible
material must be installed above the heaters
described in this manual.

Noncombustible materials, such as slate and
marble, must be at least

1/2

" thick.

Figure 2

Noncombustible

Material

A

Heater in Fireplace

or Firebox

Follow these instructions carefully to ensure
safe installation. Failure to follow these require-
ments may create a fire hazard.

Step 1. Sidewall Clearances: The sides of the
fireplace opening must be at least 16" from any
combustible side wall (

Figure 1 ).

Figure 1

Step 2. Ceiling Clearance: The ceiling must be
at least 42" from the top of the heater opening
(

Figure 1 ).

16"

Min.

42"

Min.

Heat Resistant

Material

12"

28"

34-1/2"

38-5/8"

42"

10"

2-1/2"

6"

8"

Ceiling

Advertising