RATINGS CHART – OIL BOILERS

XL-2000

©Slant/Fin Corp. 2007

SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600

FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario

www.slantfin.com

®

NOM. RECT
X HEIGHT

(in x in x ft)

XL-20

0.65

91,000

78

68

8 x8x15

6 x 15

83.56

8

11

16

"

4

9

16

"

6"

1

1

4

"

25

3

8

"

304

XL-30H

0.85

119,000

104

90

8 x8x15

6 x 15

86.00

12

3

6

"

6

5

16

"

6"

1

1

4

"

28

7

8

"

382

XL-30

1.00

140,000

121

105

8 x8x15

6 x 15

85.04

12

3

16

"

6

5

16

"

6"

1

1

4

"

28

7

8

"

1.15

161,000

138

120

8 x8x15

6 x 15

84.12

12

3

16

"

6

5

16

"

6"

1

1

4

"

28

7

8

"

XL-40H

1.25

175,000

152

132

8 x8x15

7 x 15

86.00

15

11

16

"

8

1

16

"

7"

1

1

4

"

32

3

8

"

482

XL-40

1.35

189,000

162

141

8 x8x15

7 x 15

85.05

5

11

16

"

8

1

16

"

7"

1

1

4

"

32

3

8

"

1.55

217,000

186

162

8 x8x15

7 x 15

84.38

5

11

16

"

8

1

16

"

7"

1

1

4

"

32

3

8

"

XL-50

1.80

252,000

217

189

8 x8x15

8 x 15

85.00

19

3

16

"

9

13

16

"

8"

1

1

2

"

35

7

8

"

2.00

280,000

239

206

8 x8x15

8 x 15

84.19

19

3

16

"

9

13

16

"

8"

1

1

2

"

35

7

8

"

BOILER

MODEL

NO.

GPH

BTUH

I=B=R

BURNER

CAPACITY

OIL INPUT

§

D.O.E.

HEATING

CAPACITY

MBH *

WATER

I=B=R

WATER

NET

RATING

MBH *

I=B=R

CHIMNEY SIZE

I.D. ROUND

X HEIGHT

(in x ft)

AFUE %

WATER

Standard working pressure 30 psi.
All boilers hydrostatically tested — A.S.M.E.
*

For forced hot water heating systems where the boiler and all piping are located within the
area to be heated, the boiler may be selected on the basis of gross D.O.E. capacity output.
The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15.
D.O.E. heating capacity is divided by the allowance to obtain net rating. The Slant/Fin Technical
Service Department should be consulted before selecting a boiler for unusual piping and pick-
up requirements such as intermittent system operation, extensive piping, etc.

Ratings apply to the use of light oil at 140,000 Btu per gallon and apply only with Slant/Fin

supplied burners properly adjusted to produce 13% CO

2

.

Nominal clay tile liner dimensions.

§

Boiler models XL-30 and larger have two firing rates. The boiler is factory shipped at the lower
firing rate. To obtain the higher firing rate, refer to the XL-2000 boiler installation instructions for
the appropriate field adjustments.

Oblong flue collar. Fits 6" dia. vent connectors.

NOTE: All boilers under 300,000 Btuh input are tested and rated for capacity under the U.S.
Department of Energy (D.O.E.) Test Procedures for Boilers.

BOILER

LENGTH

“A”

FRONT

TO

FLUE

“B”

FLUE

COLLAR

DIA.

“C”

CIRCULATOR

SUPPLY

FLANGE “D”

NPT

APPROX.

OVERALL

LENGTH

“E”

SHIPPING

WEIGHT

(lbs.)

382

482

538