STORAGE TIPS

If you do not plan to use your humidifier for an extended period of time, such
as during the summer months, it is important that you follow these instructions
to help prevent problems from developing in the unit.

1. Clean your humidifier as instructed in the section titled, “Cleaning and

Maintenance”.

2. Make sure all water is emptied from the tank and the hot and cold water

reservoirs.

3. Dry your unit thoroughly.
4. Leave the tank cap off to expose the tank to air.
5. Pack your humidifier in its original carton and store it in a cool, dry place.

SERVICE

DO NOT attempt to repair this humidifier yourself. For repairs covered under
the warranty, contact Slant/Fin by telephone or mail for a Return Authorization
Number. Have other repairs professionally performed.

GLOW

It is normal to see the humidifier glow when operating in a darkened room.
This glow results from the internal illumination of the 3.5 watt UV bulb.
However, no ultraviolet light, even at this harmless level, passes through the
UV-proof cabinet into the room.

TROUBLESHOOTING

TROUBLE

POSSIBLE CAUSES

SOLUTION

Unit does not mist

Unit is not plugged in

Plug in unit

Power failure

Check circuit breaker

Water tank empty

Remove and refill

Power switch not turned on

Turn on switch

Unit not reset after refilling tank

Check that there is
water in the hot water
reservoir.

Water tank not properly

Reposition water tank

located on base unit
Humidity level set is achieved

Turn Relative
Humidity Control to
higher setting

Water leaks from unit Drain cap, drain cap gasket,

Tighten cap. Replace

tank cap or tank cap gasket

or reposition cap

is missing or improperly

gasket.

positioned.

Moist air output low

Mineral buildup in hot water

Clean unit as per

reservoir.

instructions.

9

CHANGING THE UV GERMICIDAL BULB

1. If the “REPLACE UV BULB” indicator

illuminates during normal use, it is time
to change the UV germicidal bulb,
which is a special 3.5W bulb.

2. Turn the ON-OFF switch to the “OFF”

position, unplug it and allow it to cool.

3. Remove the water tank from the base

of the humidifier.

4. Place the base of the humidifier over the sink and tilt the unit to remove any

remaining water.

5. Carefully turn the base of the humidifier over and place it upside

down on a flat level surface. You will see a door that is closed with a screw.

6. Using a Phillips head screwdriver, carefully turn the screw counterclockwise

until the screw separates from the door.

7. Open the door. The UV germicidal light bulb will be visible.

8. Take a replacement 3.5W UV germicidal bulb that you purchased from

Slant/Fin Corporation or another supplier and change the bulb. To prolong
the life of the bulb, limit your direct contact with the glass of the bulb by using
a cloth or tissue to screw it into place.

9. When the new bulb is in place, close the door and replace the screw by using

your Phillips head screwdriver and rotating it clockwise until it is just tight. DO
NOT OVER TIGHTEN.

10. Turn the unit upright, place the water tank on top of the base of the humidifi-

er, plug the unit in, and turn the ON-OFF switch to the “ON” position. The
“REPLACE UV BULB” indicator should no longer be lit.

IMPORTANT NOTE: Even though you will not receive maximum germicidal
effects, you can still use your GF-200 and GF-210 humidifier until the replace-
ment bulb arrives.

8

Advertising