3 allowable static electricity level, 4 vibration test, 5 drop test – Star Micronics TUP482-24 User Manual

Page 31

Advertising
background image

– 27 –

14.3 Allowable Static Electricity Level

Notes)

Use SLS-060P-50 (Sanken) as the power source.

The reference data is shown in the table above; this data may differ depending on the installa-

tion conditions.

14.4 Vibration Test

14.5 Drop Test

Quality control

test specifications

Direct discharge

Element allowable level
(self-printing)

±

8 kV (*1)

No fracturing of elements allowed

±

15 kV

Indirect discharge

Element allowable level
(self-printing)

±

15 kV

Checker connection allowable level
(continuous printing)

±

3 kV (*2)

Direct discharge error:

5%

(*1)

±

10 kV test is also performed.

Indirect discharge error: 0%

(*2)

±

5 kV test is also performed.

Item

Specification

Frequency

7 ~ 100 ~ 7 Hz (sweeping: 2.5 minutes)

Amplitude

15.3 ~ 0.07 mm

Gravity

1.5 G (constant)

Vibration direction and
time

1 hour in each direction: X, Y and Z
Total of 3 hours

Packing

As small as possible

Item

Specification

Drop height

80 cm

Drop sequence

One corner, three edges and six surfaces

Packing

As small as possible