7 near-end sensor position – Star Micronics TUP482-24 User Manual

Page 19

Advertising
background image

– 15 –

6.7 Near-End Sensor Position

<Technical Specifications>

The near-end sensors can be moved a maximum of 5 mm to the right or left by moving the near-end

sensor PCB.

Slightly loosen the three screws (without removing them) used to install the PCB, then move the PCB

to the desired position. After making sure that the PCB fits properly (i.e. it is not loose), tighten the

three screws. (Do not break the PCB.)

* The near-end sensors are mounted on the back of the PCB.

Near-end sensor PCB

Near-end sensor NEB

Near-end sensor NEA

Square hole

Side frame

Slot

Can be moved a maximum
of 5 mm to the right and left

Screw

Advertising