Cyprus and aruba (50 hz), Wiring diagram cyprus and aruba export (50 hz), Page 32 – Sundance Spas Maxxus User Manual

Page 35

Advertising
background image

Page 32

Electrical Wiring Diagram

Cyprus and Aruba Export (50 Hz)

OZONA

T

O

R

O

3

GRN

TB1

N

N

RED

N

L

L(BRN)

N

L(BLK)

N

L

L

BLK

L

2

1

HEA

TER

2.7 kW @ 230 V

A

C

17

HI - LIMIT

/ FREEZE SENSOR

TEMPERA

TURE SENSOR

J1

J2

J3

F1

20A, 250V

SC-20

HOT

TUB

LIGHT

TRANSFORMER

230 V

A

C

Cyprus /

Aruba Panel Shown

J4

BK

JP1

4

2

3

1

230 V

AC, 1 PHASE, 50 Hz

USE COPPER CONDUCT

ORS ONL

Y

WIRE SIZE MUST BE

APPROPRIA

TE

PER NEC

AND/OR LOCAL

CODES

PUMP

HI

LO

THERM

SWITCH

PRESSURE SWITCH

Advertising