1 graphical eq display, Operational overview – Solid State Logic X-EQ User Manual

Page 13

Advertising
background image

5.1 Graphical EQ Display

When you click on any of the EQ band nodes on the display

the corresponding band parameters will be shown in the Band

Control section on the right. These can be adjusted with the

mouse cursor, scroll wheel or numerically using the keyboard.

The colour of the node corresponds to the colour on the Band

Section and the Band Selector.
Mouse Operations in Graphical Display
Click and hold on any bell or shelf node to move it in two

dimensions simultaneously:
• Gain

Mouse drag Up/Down

• Freq

Mouse drag Left/Right

When moving the LP and HP filter nodes:
• Order

Mouse drag Up/Down

• Freq

Mouse drag Left/Right

5.2 Control Options in Band Control and Input/Output

Sections
Move the mouse cursor either up/down or

in a circular movement over a knob to

adjust it’s parameter value. The exact

nature of the movement you need to make

to change a knob value is dictated by your

DAW.
The scroll wheel can also be set to alter

parameter values here.
Press ‘Shift’ whilst scrolling for increased

resolution.
Command + Click (Mac) or Ctrl + Click

(PC) on a knob to reset it to it’s default

value.

Exact numerical entry is possible by double clicking on the

value box.

9

5. Operational Overview

Advertising