6.5 Voltage

Regulation

STATUS

Required

The power supply output voltages must stay within the following voltage limits when operating at steady state and
dynamic loading conditions. These limits include the peak-peak ripple/noise specified in Section 5.8. All outputs
are measured with reference to the return remote sense (ReturnS) signal. The 5 V, 12V1, 12V2, 12V3, –12 V and
5 VSB outputs are measured at the power supply connectors referenced to ReturnS. The +3.3 V is measured at
its remote sense signal (3.3VS) located at the signal connector.

Table 18: Voltage Regulation Limits

Parameter MIN NOM MAX Units Tolerance

+3.3

V

+3.20 +3.30 +3.46 V

rms

+5/-3%

+5

V

+4.80 +5.00 +5.25 V

rms

+5/-4%

+12V1

+11.52 +12.00 +12.60 V

rms

+5/-4%

+12V2

+11.52 +12.00 +12.60 V

rms

+5/-4%

+12V3

+11.52 +12.00 +12.60 V

rms

+5/-4%

-12

V

-11.40 -12.20 -13.08 V

rms

+9/-5%

+5

VSB

+4.85 +5.00 +5.25 V

rms

+5/-3%

STATUS

Optional

Some system applications may require tighter regulation limits on the +5 V output. The optional regulation limits
are shown below.

Table 19: Optional +5V Regulation Limits

Parameter MIN NOM MAX Units Tolerance

+5

V

+4.85 +5.00 +5.25 V

rms

+5/-3%

- 19 -