How to add and test pcie cards, Test hard drives – Sun Microsystems Sun FireTM X4150 User Manual

Page 10

Advertising
background image

8

Sun Fire X4150 Configuration Guide • March 2009

Test Hard Drives

Note –

To expedite hard drive testing use the 1% test coverage.

How to Add and Test PCIe Cards

Slot0 - slot2 can accommodate x16 mechanical cards.

The disk controller HBA card must be inserted into slot 1 (the middle slot).

After installation, update the firmware level for each card as specified by the
manufacturer.

4

Use the insert key to add drive 0 to the Selected Drives list on the right and press
enter.

5

Label the volume (you can use the drive volume number) and press Enter

6

Accept the defaults for Read Caching and Write Caching and press Enter.

7

Select Build for the Create RAID Via option and press Enter

8

Press Enter to build the volume.

9

Repeat the steps to create a volume for each drive.

Testing Hard Drives Using Pc-Check

1

Boot the server with the Tools and Drivers CD to access the diagnostics.

2

Select the option to Run Hardware Diagnostics.

3

Select the option to test hard drives.

Adding PCIe Cards

1

Connect PCIe cards to a riser assembly.

2

Insert the PCIe card and riser assembly into a PCIe slot on the motherboard.

3

Update the firmware level for each card as specified by the manufacturer.

Testing PCIe Cards

1

If the option exists invoke the cards built in self-test.

2

Test the card by performing basic rudimentary activities. For example, establish
network connectivity (for a GigabitEthernet card).

Verifying Hard Drives Using the Adaptec-based Sun StorageTek PCIe SAS 8-port Internal HBA

Advertising