B3

DIGITAL AUDIO FRAME – Unbalanced (MRX-CDAF)

Signal Type........................................................AES-3id 1995

Connectors ........................................................75 Ohm BNC

Inputs.................................................................32, single-ended, terminated, 1V p-p max.

Input return loss .................................................15 dB min. from 0.1 MHz to 6.0 MHz

Input impedance ................................................75 ohms from 0.1 MHz to 6.0 MHz

Input cable length ..............................................1000 feet maximum

Outputs ..............................................................32, single-ended, 1V p-p max.

Output return loss ..............................................15 dB min. from 0.1 MHz to 6.0 MHz

Output impedance..............................................75 ohms from 0.1 MHz to 6.0 MHz

Output Rise and Fall time...................................30ns < tr < 44ns, 10% to 90% (rise time)

30ns < tf < 44ns, 10% to 90% (fall time)

Serial Data Rates...............................................3.072 Mb/s max. ( Fs = 48 kHz max.)

Serial Data Jitter ................................................±20ns p-p max.

Reclocking .........................................................Automatic

Electrical length .................................................80ns typical

Operating temperature.......................................0 to 50 degrees Celsius

POWER SUPPLY FRAME (MRX-PSF)

AC Input Voltage................................................100-240 VAC, 50-60 Hz

AC Input Connectors..........................................3 pin IEC (2 total per frame)

Power Supply Type ............................................AC-DC Switching, forced air cooling

Removable Supply Model Name ........................MRX-PSU

Max. Removable Supplies..................................2 in non-redundant configuration

4 in redundant configuration

DC Outputs ........................................................2 per MRX-PSU (8 total per frame)
DC Output Connectors.......................................4 pin for MRX Analog

6 pin for MRX Digital

DC Output Voltage.............................................±18VDC for MRX Analog

Dual +18VDC for MRX Digital

AC Input Power..................................................85W Supplying Maximum Load for MRX Digital

Includes MRX-DVF and MRX-TDAF (or CDAF)

60W Supplying Maximum Load for MRX Analog

Includes MRF-V and two frames of MRF-A

120W Supplying Max. Load for MRX Analog & Digital

Operating temperature.......................................0 to 50 degrees Celsius

MECHANICAL

Switch and Power Frame ...................................1 RU

1.75” H x 19” W x 10” D

Master Control Panel (SYX &SYX-3232) ...........2 RU

3.5” H x 19” W x 2.5” D

Single Bus Panels (SBX-32) ..............................2 RU

3.5” H x 19” W x 2.5” D

Alpha-Numeric (ANX) .......................................1 RU

1.75” H x 19” W x 2.5” D

Rapid Take Panel (RTX-32)...............................1 RU

1.75” H x 19” W x 2.5” D