John Wood Oil-Fired User Manual

Page 7

Advertising
background image

– 7 –

600mm (24 in.) MIN.

FOR SERVICING

457mm

(18 in.)

MIN.

FLUE

SEE TABLE

TOP

SEE TABLE

FLUE SIZES

SEE TABLE

NON-COMBUSTIBLE FLOOR

COMBUSTIBLE CEILING

DRAFT

REGULATOR

FLUE

SEE TABLE

Figure 1 Rough-In Dimensions

NOTE: JWF307V requires additional
“Through-the-wall Vent Kit” available
in 3 lengths: 5’ (63320), 10’ (63321)
or 20’ (63322). Refer to additional
“Installation Instructions for Through-
the-wall Venting Components" that is
supplied with the JWF307V.

Center Rear

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

JWF307

508

20

X

152

6

610

24

51

2

51

2

457

18

229

9

JWF507

559

22

X

152

6

610

24

51

2

51

2

457

18

229

9

JWF657

660

26

X

152

6

610

24

51

2

51

2

406

16

152

6

JWF307V

508

20

X

152

6

610

24

51

2

51

2

457

18

152

6

JW317

610

24

X

152

6

610

24

152

6

152

6

356

14

457

18

JW327

610

24

X

X

152

6

610

24

152

6

152

6

356

14

457

18

JW517

711

28

X

178

7

610

24

152

6

152

6

356

14

457

18

JW527

711

28

X

X

178

7

610

24

152

6

152

6

356

14

457

18

JW717

813

32

X

178

7

610

24

152

6

152

6

356

14

457

18

JW727

813

32

X

X

178

7

610

24

152

6

152

6

356

14

457

18

Model

Diam.

Flue size

Front

Flue location

Clearance

Rear

Sides

Top

Flue

Advertising