Maintenance, Pressure w asher – Shark SSG-503537E/G User Manual

Page 14

Advertising
background image

SHARK SSG • 8.914-337.0 / 97-6134 • Rev. 8/07

OPERA

TOR’S MANU

AL

PRESSURE

W

ASHER

14

Coil Removal:

Removal of coil because of freeze breakage, or to clean
soot from it can be done quickly and easily.
1. Disconnect hose from pump to inlet side of the

coil.

. Carefully disconnect the thermostat sensor making

sure you do not crimp the capillary tube.

3. Remove burner assembly from combustion cham-

ber.

4. Remove the 3-3/8" bolts from each side of coil and

tank assembly (these bolts are used to fasten tank
to chassis).

5. Remove fittings connected to the 1/" pipe nipples

from inlet and discharge sides of coil.

6. Remove top tank wrap, bend back insulation tabs

and fold back blanket.

7. Remove bolts that hold down coil to bottom wrap.
8. Remove coil.
9. Replace or repair any insulation found to be torn

or broken.

10. Remove insulation retainer plates.

Coil Reinstallation:

Reinstall new or cleaned coil by reversing Steps 9
through 1.

MAINTENANCE

Advertising
This manual is related to the following products: