Mounting the SonicWALL CSM

The above SonicWALL appliances are designed to be mounted in a standard 19-inch
rack mount cabinet. The following conditions are required for proper installation:

Use the mounting hardware recommended by the rack manufacturer and ensure that
the rack is adequate for the application. SonicWALL includes a rack mounting kit with
the SonicWALL CSM that is compatible with most computer equipment racks.

Four mounting screws, compatible with the rack design, must be used and hand
tightened to ensure secure installation. Choose a mounting location where all four
mounting holes line up with those of the mounting bars of the 19-inch rack mount
cabinet.

Mount in a location away from direct sunlight and sources of heat. A maximum
ambient temperature of 104º F (40º C) is recommended.

Route cables away from power lines, fluorescent lighting fixtures, and sources of
noise such as radios, transmitters, and broadband amplifiers

Ensure that no water or excessive moisture can enter the unit.

The included power cord is intended for use in North America only. For European
Union (EU) customers, a power cord is not included.

Allow unrestricted airflow around the unit and through the vents on the side of the
unit. A minimum of 1 inch (25.44mm) clearance is recommended.

Mount the SonicWALL appliances evenly in the rack in order to prevent a hazardous
condition caused by uneven mechanical loading.

Consideration must be given to the connection of the equipment to the supply circuit
and the effect of overloading the circuits has minimal impact on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate
ratings must be used when addressing this concern.

Reliable grounding of rack-mounted equipment must be maintained. Particular
attention must be given to power supply connections other than direct connections to
the branch circuits such as using power strips.

German Language Regulatory and Safety Instructions

Hinweis zur Lithiumbatterie

Die in der Internet Security appliance von SonicWALL verwendete Lithiumbatterie darf
nicht vom Benutzer ausgetauscht werden. Zum Austauschen der Batterie muss die
SonicWALL in ein von SonicWALL autorisiertes Service-Center gebracht werden. Dort
wird die Batterie durch denselben oder entsprechenden, vom Hersteller empfohlenen
Batterietyp ersetzt. Beachten Sie bei einer Entsorgung der Batterie oder der SonicWALL
Internet Security appliance die diesbezüglichen Anweisungen des Herstellers.