SECO-LARM USA Enforcer SA-025 User Manual

Enforcer, Sa-025 timer module, Other products available from seco-larm

Advertising
background image

TimerPdf070103.pmd

Other Products Available from SECO-LARM

Power Supply/Chargers

ST-2406-5A

ST-2406-3A

ST-2406-2A

ST-1206-1.5A

Model #

ST-1206-1.5A
ST-2406-2A
ST-2406-3A
ST-2406-5A

Voltage

DC

6,12

6,12,24
6,12,24
6,12,24

Current

(continuous)

1.5A
1.5A
2.5A
4.0A

Current

(peak)

2.0A
2.0A
3.0A
5.0A

5-Amp relay, DPDT, Form-C.

6/12/24 VDC operation.

LED indicates power.

Relay Board

SR-2224-C5

Relay can be wired for load

switching, dry contact, latching,

reverse polarity, line seizure, etc.

Plus many, many other
products for commercial,
residential and vehicle
security. See our website for
details, or contact us for a
catalog .

ENFORCER

®

The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is not responsible for misprints.

For more information, contact:

Tel: 1-800-662-0800 (domestic U.S. & Canada)

Tel: 1-949-261-2999 (California & international) Fax: 1-949-261-7326 Email: [email protected]

Website: www.seco-larm.com

SA-025 Timer Module

The SA-025 Programmable Timer Module is suitable for a wide range
of timed security and access control operations, such as door unlock
timing, siren or bell timer, and so on. Auto-sensing of input voltage
and DIP switches for programming make installation easy.

Timer can be set from 1 sec. to 60 minutes

Can be triggered by positive voltage (+DC),

or closure or opening of dry contact.

Relay can be programmed to activate at the

start or at the end of the timing cycle

Relay can also be set to activate for one

second at the end of the timing cycle

Programmable for pulse (flash) activation

Built-in reset function to manually reset

timing cycle

Form-C relay, contacts rated 8A @

120VAC/24VDC

LED indicates relay is energized

12VDC/24VDC operation (auto sensing)

DIP switch settings

SwitchFunction

ON

OFF

#1 Timing starts:

At end of trigger

At start of trigger

#2 How does the timing start?

When the module is powered up Connecting (+) to TRG

#3 Timer setting:

In seconds

In minutes

#4 Steady relay output, or pulse/flash?

Steady relay output

Pulse/flash output

#5 When does the relay output start?

At end of timing period

At start of timing period

#6 Relay output mode, delayed or instant?

Instant output

Delayed output

Current draw - 3mA (standby) or 40mA

(relay energized)

Board measures 2

7

/

8

" x 2

1

/

2

" (73 x 63 mm)

Functions programmed via DIP switches -

no jumpers to cut

Advertising