The level shifter must be a V28 electrical signal compliant with 2.8V.

Figure 7. Example of RS-232 Level Shifter Implementation for UART

Note that the U1 chip also protects the WISMO218 against ESD (Air Discharge) at 15KV.

Table 8.

Recommended Components

Component

Description/Details

Manufacturer

R1, R2

15K

C1, C2, C3, C4, C5

1µF

C6

100nF

C7

6.8uF TANTAL 10V CP32136

AVX

U1

ADM3307EACP

ANALOG DEVICES

J1

SUB-D9 female

R1 and R2 are necessary only during Reset state to force the ~CT125/RI and ~CT109/DCD signals to
HIGH level.

The ADM3307EACP can be powered by the VCC_2V8 (pin 46) of the WISMO218 or by an external
regulator at 2.8V.

If the UART interface is connected directly to a host processor, it is not necessary to use level shifters.