Cleaning the air filter – Sony VPL-CS1 User Manual

Page 30

Advertising
background image

VPL-CS1

4-074-278-11 (1)

C:\MUN\Data\FM\VPL-CS1\VPL-
CS1.nouhindata\407427811VPLCS1WW\02GB-
VPLCS1WW\06MNT.fm

masterpage:Left

GB

30

Maintenance

6

Turn the projector back over.

7

Connect the power cord and turn the
projector to standby mode.

8

Press the following keys on the
control panel in the following order
for less than five seconds each:
RESET,

<, ,, ENTER.

• Be sure to use the LMP-C120 Projector

Lamp for replacement. If you use lamps
other than LMP-C120, the projector may
cause a malfunction.

• Be sure to turn off the projector and unplug

the power cord before replacing the lamp.

• Do not put your hands into the lamp

replacement spot, or not fall any liquid or
object into it to avoid electrical shock or fire.

The air filter should be cleaned every 300
hours. When it becomes difficult to remove
the dust from the filter, replace the filter with
a new one.
To clean the air filter, follow the steps
below:

1

Turn off the power and unplug the
power cord.

2

Turn the projector over.

3

Remove the air filter cover.

4

Remove the dust from the filter with a
vacuum cleaner.

5

Attach the air filter and replace the
cover.

• If the air filter is excessively dirty, wash it

with mild detergent solution and dry it in a
shaded place. If the dust cannot be removed,
replace the air filter with the supplied new
one.

• Be sure to attach the air filter cover firmly;

the power will not be turned on if it is not
closed securely.

• The air filter has a face and a reverse side.

Place the air filter so that it fits in a notch on
the air filter cover.

Notes

Cleaning the Air Filter

Notes

Advertising