Spectrapure – Spectra Watermakers THE MAXCAP RO/DITM SF-MT-0.5-10 User Manual

Page 8

Advertising
background image

SpectraPure

SpectraPure®Inc.

480.894.5437 Call us toll-free 1.800.685.2783

2167 East Fifth St, Tempe, Arizona 85281

®

8

1.

IMPORTANT: During the initial rinse-up of the

M

AX

C

AP

RO/DI ™, a large ionic load is

presented to the downstream DI cartridges. Be sure to rinse up all new

MAXCAP DI ™ with the downstream cartridge removed. This rinsing step will

ensure that the

MAXCAP DI ™ cartridge is initially rinsed up to produce high quality

water before connecting your downstream cartridge. Failure to rinse this upstream

MAXCAP DI ™ cartridge may reduce the lifetimeof your downstream DI cartridge.

2.

Remove the SilicaBuster ™ DI cartridge from the right-most housing and re-install the

empty housing on the system. Attach garden hose adapter to your cold water source.

Never run hot water (greater than 100 F (38 C)) through the system.

3.

Place the yellow concentrate tubing and the blue purified water tubing into a drain or

bucket. Do not restrict flow from these lines.

4.

Slowly open the cold water supply valve and allow the housings to fill. You may use

pressure up to 80 psi (5.5 bar). If the pressure is less than 40-PSI, a booster pump will

be required. If the pressure is greater than 80- PSI, a pressure regulator will be

required. (See “Optional Items” for the part numbers).

5.

Turn on both TDS meters. Set the left-side meter to “OUT” (Post-RO and Pre-

MAXCAP DI ™). Set the righ-side meter to “IN” (Post-MAXCAP DI ™).

6.

When the right-side meter reads zero, turn the cold water feed off and place the

SilicaBuster™ DI cartridge back into its housing.

7.

Turn the cold water feed back on and run the system until the “OUT” probe of the

rigt-hand meter reads zero.

8.

Now test the concentrate to purified water ratio on page 9-12.

CHECK:

- Ensure that all fittings are tight and leak-free before leaving the system

unattended.

- The concentrate line (yellow) includes a smaller capillary tube (flow restrictor)

that is located “inside” of the tubing. Do not remove or discard this restrictor;

the system will not produce permeate water without the flow restrictor.

- All of the following conditions must be met before water will flow through the

system. The water source must be turned “ON” and the water level in the

reservoir tank must be below the low level float, if present.

Note: It is recommended that at least 2 gallons (7.57 liters) of purified water be discarded
before collecting purified water for use. If the unit is not used for
several days, run the system for at least 15 minutes before collecting any water.

Upon start-up, air may be trapped in the DI cartridges (housing may not appear full), this is
a normal condition and it will not affect the operation of the DI system

.

SYSTEM INITIALIZATION

If you are setting up your system for the first time or replacing the

RO membrane, please see the “Checking the Concentrate to

Purified Water Ratio” .

SpectraPure®Inc.

Fax 480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

17

SpectraPure

®

Reconnect the tubing to the membrane housing. Place the

flow restrictor in a safe location where it will not be accidentally

crushed or damaged.

11. Put the yellow concentrate tubing and the blue product

water tubing in the drain and turn on the system water supply.

Allow the system to flush for several minutes.

12. Turn off the water supply to the system. Remove the yellow

tubing from the membrane housing and replace the flow restrictor.

13. Re-insert the flow restrictor end of the yellow tubing into

its push-fitting at the RO membrane and reconnect the yellow

concentrate tubing to the membrane housing.

14. Turn on the water supply to the system and check for leaks. Check,

and if necessary adjust, the Concentrate to Purified Water Ratio per

the

procedures.

Fig. F: Removing the Membrane Element

Fig. G: Inserting the New Membrane Element

black

membrane

brine seal

black

membrane

housing

O-ring

membrane

product

water tube

double

O-ring end of

membrane

product

water stem

tube

Advertising
This manual is related to the following products: