Sierra Monitor Corporation 4100-34 User Manual

Model 4100 series, Gas sensor modules, Specifications

Advertising
background image

Model 4100 Series

Gas Sensor Modules

Sierra Monitor Corporation 1991 Tarob Ct. Milpitas, CA 95035 (408) 262-6611 800-727-4377 FAX: (408) 262-9042

Visit our Web site at: www.sierramonitor.com E-Mail: [email protected]

The Model 4100 Series Gas Sensor Modules

monitor a variety of toxic and combustible gases

and provide a 4-20 mA DC output signal of gas

concentration

The Model 4100 Series utilizes semiconductor sensor tech-

nology to provide monitoring of gases in the parts per mil-

lion (PPM) ranges. These modules operate on 24 VDC

input and have a non-linear 4-20 mA DC current loop out-

put.

The four gas sensor modules in this series are:

4100-33 Gas Sensor Module 4-20 mA DC

4100-34 Gas Sensor Module 4-20 mA DC

4100-35 Gas Sensor Module 4-20 mA DC

4100-36 Gas Sensor Module 4-20 mA DC

These gas sensor modules can monitor a wide variety of

gases. Table A provides a partial list of gases that can be

reliably monitored. If your gas is not on this list, check

with Sierra Monitor to determine if a 4100 Series gas sen-

sor module is available to meet your requirements.

Also, these gas sensor modules can be calibrated with

the gas of interest or with methane or carbon monoxide.

Thus, the user does not have to obtain a special calibra-

tion gas.

The Model 4100 Series provides a non-linear 4-20 mA out-

put signal that can interface with the Sierra Monitor Sensys

controller or other linearizing controllers / indicators. Curves

and linearizing equations can be provided for a specific

gas and sensor to enable the operation of these sensor

modules with other brand controllers.

Specifications

Sensor

Type:

Solid State Metal Oxide Semiconductor

Range:

20-500 ppm or 50-5000 ppm See Table A.

Response:

80% of concentration in less than 3 mins.

Typical Life:

1-3 years in Normal Service.

Detectable Gases And Vapors

Typical List:

See Table A

Maintenance

Calibration

Adjustments: Zero Adjust, Span Adjust

Sensor LED:

OFF indicates heater or film is an open circuit.

Environmental

Operating:

Temperature -10

o

C to +40

o

C (14

o

F to 104

o

F)

Humidity 5% to 95% non-condensing

Storage:

Temperature -55

o

C to +85

o

C (-67

o

F to 185

o

F)

Electrical Data

Wiring:

3 wire non-isolated

Input Voltage: 14 - 30 VDC

Current:

70mA @ 4mA DC loop current;

90mA @ 20mA DC loop current at 24VDC.

Power:

2.1 Watts

Output Range: 4-20mA DC Non-linear

Loop Res.:

800 ohms at 28VDC

Mechanical

Size:

6.75" x 4" x 3.5" (HxWxD)

(17.1 cm x 10.2 cm x 8.9 cm)

Material:

Cast aluminum epoxy painted

Weight:

2 pounds (0.9 Kg)

Classification: Class I Division I Groups C,D
Mounting:

Connects to a vertical 3/4" electrical conduit

How it Works

Semiconductor sensors have a resistance in air that is

affected by oxygen adsorbed on the surface of the sensor.

Oxygen atoms capture electrons on the semiconductor

surface, thereby increasing its resistance.

The sensors can be impregnated with dopants such that

the sensor’s resistance changes when specific gases dis-

place the adsorbed oxygen.

Nobel Metal Wire

Sensor

Heater Coil

Advertising
This manual is related to the following products: