Command List

VISCA Device Setting
Command

Before starting control of the FCB series camera, be
sure to send the Address command and the IF_Clear
command using the broadcast function.

For VISCA Network Administration

Address

Sets an address of a peripheral device. Use when
initializing the network and when receiving the
network change message indicated below.

Network Change

Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.

Packet

Note

Address

88 30 01 FF

Always broadcasted.

Network Change

X0 38 FF

X = 9 to F: FCB series camera address + 8

VISCA Interface Command

IF_Clear

Clears the command buffers in the FCB series
camera and cancels the command currently being
executed.

Command Packet Reply Packet

Note

IF_Clear

8X 01 00 01FF

X0 50 FF

IF_Clear (broadcast)

88 01 00 01 FF

88 01 00 01 FF

X = 1 to 7: FCB series camera address (For inquiry packet)
X = 9 to F: FCB series camera address +8 (For reply packet)

VISCA Interface and Inquiry

IF_DeviceTypeInq

Returns information on the VISCA interface.

Inquiry

Inquiry Packet Reply Packet

Description

IF_DeviceTypeInq

8X 09 00 02 FF Y0 50 GG GG HH GGGG = Vender ID
HH JJ JJ KK FF (0020: Sony)

HHHH = Model ID
042E=FCB-IX11A
042F=FCB-IX11AP
JJJJ = ROM revision
KK = Maximum socket # (02)

X = 1 to 7: FCB series camera address (For inquiry packet)
X = 9 to F: FCB series camera address +8 (For reply packet)