LT-12 SERIES LIGHT TOWER — OPERATION MANUAL — REV. #1 (08/15/08) — PAGE 7

LT-12 SERIES LIGHT TOWER — RULES FOR SAFE OPERATION

The

5 DANGER

items listed below are considered

High DANGER

areas and should be adhered to. Failing to

understand these areas could result in

Bodily Harm,

Electrical

Shock

,

Electrocution

, and even

Death! Please

pay close attention when operating the light tower.

The LT-12 Light tower is equipped with
a

ground terminal

for your protection.

ALWAYS complete the

grounding

path

from the light tower to an external

grounding source.

ALWAYS make certain the light tower is well grounded and
securely fastened to a good earth ground (ground rod). The
possibility exists of

Electrical Shock, Electrocution, and

even Death

if the light tower is not grounded.

NEVER operate the LT-12 Light tower
or handle any electrical equipment
while standing in water, while bare
foot, while hands are wet, or in the
rain. A dangerous

electrical shock

could occur causing

Severe Bodily Harm or even Death.

ALWAYS keep electrical cords in good condition. Worn,
bare or frayed wiring can cause electrical shock, thus
causing

Bodily Harm or even Death

.

NEVER grab or touch a live power
cord with wet hands, the possibility
exists of

Electrical Shock,

Electrocution, and even Death!

POWER

CORD

(POWER ON)

WET

HANDS

ALWAYS make sure the area
above Light tower is open
and clear of overhead power
lines and other obstructions.
The tower extends in excess
of 30 ft. (9 meters). Contact
with overhead powerlines or
other obstructions could result
in equipment damage,

Serious Injury or Death

!

NEVER touch bulbs while in use. Bulbs become extremely

hot when in use! Allow bulbs and fixture to cool at least 10-
15 minutes before handling.

ALWAYS retract the mast before lowering the tower to

transport position.

Maintenance Safety
NEVER lubricate components or attempt service on a running

light tower/generator.

ALWAYS allow the light tower/generator a proper amount of

time to cool before servicing.

■ Keep the light tower/generator in proper running condition.
■ Fix damage to the light tower/generator immediately and

always replace broken parts.

Emergencies
ALWAYS know the location of the

nearest

fire extinguisher

.

ALWAYS know the location of the nearest

first aid kit

.

■ In emergencies

always

know the location of the nearest phone

or

keep a phone on the job site

. Also know the phone

numbers of the nearest

ambulance

,

doctor

and

fire

department

. This information will be invaluable in the case

of an emergency.

NEVER use the light tower mast as a crane. DO NOT lift

anything with the mast.

NEVER attach anything to the light tower mast.
ALWAYS keep the immediate area surrounding the light

tower clean, neat, and free of debris.

ALWAYS lower the tower when not in use, or if high winds or

electrical storms are expected in the area.

NEVER pivot or retract mast while unit is operating.

DANGER - High Danger Areas

DANGER - Grounding the LT-12 for Operation

DANGER - Electric Shock Hazards

DANGER - Overhead Obstruction Danger