1-9. Replacing and Adjusting the Switching Regulator

1-9. Replacing and Adjusting the

Switching Regulator

After replacing the switching regulator, be sure to adjust

the power supply voltage.
To adjust the power supply voltage, require the power

supply tool.

1-9-1. Replacing the Switching Regulator

c
Turn off the power of the power supply unit requiring the
switching regulator replacement and unplug the power

plug from the outlet before starting the replacement.

1.

Remove the front panel. (Refer to Section 1-2.)

2.

Remove the power supply unit that contains the

switching regulator to be replaced.
(Refer to Section 1-6.)

3.

Remove the six screws.

4.

Release the two harnesses (AC and DC) from the two

wire clampers, then disconnect them from the
switching regulator.

5.

Disconnect the harness GND from the switching
regulator.

Wire clamper

Wire clamper

Harness DC

Harness AC

PSW 3

x

6

PSW 3

x

6

Harness GND

PSW 3

x

6

B 3

x

6

6.

Open the insulated plate and then remove the
switching regulator.

7.

Install a new switching regulator in the reverse order
of steps 3 to 6.

8.

Adjust the power supply voltage.
(Refer to Section 1-9-2.)

9.

Reinstall the adjusted power supply unit in the
PFV-L10 and then reattach the front panel.