Specifications – Senco PC1010 User Manual

Page 15

Advertising
background image

14

TROUBLESHOOTING

PROBABLE CAUSE

Restricted air intake filter.

Defective (reed) valve.

REMEDY

Clean.

Drain air tank and measure pump up time. Compare to

specifications. If lower, remove pump head and inspect

valve plate, clean or replace.

Symptom 10. Air compressor not making enough air.

Symptom 11. Moisture in discharge air.

PROBABLE CAUSE

Condensation in air tank caused by high level

of atmospheric humidity or air compressor is

not run long enough.

REMEDY

Drain air tank after every use. Drain air tank more often

in humid weather and use an air line filter.

15

SPECIFICATIONS

Model #

PC 1010

Motor

Horsepower

0.5HP

Voltage

115

Amperage

4

Hz.

60

Phase

Single

RPM

3400

Compressor Pump

Number of Cylinders

1

Compression Stage

1

Crankcase

Aluminum

Bearings

Ball

Cylinder

Aluminum

Valves

Reed-Single

Head

Aluminum

Filter

Insert

Motor/Pressure Switch Setting

Cut-out

120 PSI

Cut-in

90 PSI

Controls

Start/stop

Air tank

Capacity

1 gallon

Performance

CFM Air Displacement

1.4

CFM @ 40 PSI

1.0

CFM @ 90 PSI

0.6

CFM @ 100 PSI

0.5

Maximum Pressure

120 PSIG

Pump-up Time: 0-120 PSI

2 min., 30 sec.

Recovery Time:

90-120 PSI

60 seconds

Weight

Net

20 Ibs.

Dimensions

Basic LxWxH

14"x13"x10"

Advertising