Installation instructions, Exhaust length calculation, Exhaust directions – Samsung DV665JS User Manual

Page 8: Exhaust duct locating dimensions, Special accessory, Table 1: recommended maximum length

Advertising
background image

A-2

SAMSUNG Clothes Dryers Owner’s Instructions

EXHAUST LENGTH CALCULATION

Table 1: RECOMMENDED MAXIMUM LENGTH

ELECTRIC DRYERS

Weather Hood Type

Recommended

Use only for short run installations

4”(10.16cm)

2 1/2”(6.35cm)

No. of 90˚

elbows

Rigid

Metallic Flexible*

Rigid

Metallic Flexible*

0

14m(46ft.)

9m(30ft.)

11m(37ft.)

7m(24ft.)

1

11m(38ft.)

7.5m(25ft.)

9m(30ft.)

6m(20ft.)

2

9m(31ft.)

6m(20ft.)

6.5m(22ft.)

4m(14ft.)

3

7m(24ft.)

5m(16ft.)

4.5m(15ft)

3m(10ft.)

* Do not use non metallic flexible duct.

EXHAUST DIRECTIONS

All dryers shipped from the factory are set up for rear exhausting. However exhausting can be on the

right or left side of the cabinet or the bottom of the dryer.

Remove access panel at back of dryer to gain access to internal ducts.

Disconnect duct exhaust from blower housing.

Remove desired knockout plate (either right or left side).

Attach a 90° elbow duct to blower housing and facing desired opening.

Reinstall rear access panel.

EXHAUST DUCT LOCATING DIMENSIONS

NOTE: Non-metallic ducts must never be used inside dryer cabinet.

SPECIAL ACCESSORY

Stacking kit (Model no:SK-2A)

You can obtain the stacking kit from your retailer.

With this kit you can combine your dryer with a Samsung

automatic washing machine to a washing and drying column.

The appliances are stacked in a space-economizing manner in this

arrangement, the washing machine at the button and the dryer at the top!