Sony HDCU-900 User Manual

Page 32

Advertising
background image

1-22 (E)

HDCU-900 MM

Page 6

System Diag (2/3) Display

No.

Contents

1

State of camera cable connection (Open/Short/NG)

2

Existence of data from the camera (

__/Wait/Sense/OK)

__ :

The communication with the camera cannot
be established.

Wait :

The communication with the camera is being
waited.

Sense : The communication with the camera is being

established.

3

State of the power supply of the camera (ON/OFF)

4

State of connection to the camera (OK/NG

*4

)

5

State of cable connection of the RCP/CNU connector of
the rear panel of the unit (Open/Connect)

6

Existence of the data from the RCP/CNU connector of
the rear panel of the unit (

__/Wait/Sense/OK)

__ :

The communication with the equipment
connected to the RCP/CNU connector cannot be
established.

Wait :

The communication with the equipment connect-
ed to the RCP/CNU connector is being waited.

Sense : The communication with the equipment connect-

ed to the RCP/CNU connector is being estab-
lished.

7

State of the power supply of the RCP/CNU connector of
the rear panel of the unit (OK/NG)

*4 : When power of the camera is supplied from the outside too, NG

appears.

Page 7

System Diag (3/3) Display

No.

Contents

1

Setting state of the intercom 1ch of the camera side
(ENG/PROD)

2

Setting state of the intercom 2ch of the camera side
(ENG/PROD)

3

Gain and control state of the microphone circuit of the
camera side (Remote/Local)

Page 8

AT Diag Display

Displays the details of self-diagnosis of the AT-141 board
of the unit.

No.

Contents

1

Setting state of the S603 switch on the AT-141 board
(1.001/1.000)

*5

2

Setting state of the S601 and S602 switches on the AT-
141 board (SD Local/SD Remote/HD Local/HD Remote)

*5

3

Setting state of delay amount (setting of the S120 switch
on the AT-141 board) when converting the format of the
HD-SDI signal (1Frame/90H)

*5

4

Setting state of the S110 switch on the AT-141 board
(Local/Remote)

*5

5

Setting state of the S111 switch on the AT-141 board
(Local/Remote)

*5

6

Setting state of the S103-4 switch on the AT-141 board
(Recall/HD ANA)

*5

7

State of the operation mode of the AT-141 board
(Normal/Test)

*5 : For details, refer to Section 1-5-1, “AT-141 Board” of “Settings of

Switches and Controls on Boards” of the separate Installation and
Maintenance Manual.

* System Diag 2/3 *

Camera Cable Connect

Data OK

Power ON

Sense OK

RCP/CNU Calble Connect

Data OK

Power OK

1
2
3
4
5
6
7

* System Diag 3/3 *

Intercom

Camera CH1 PROD

MIC ON

CH2 PROD

MIC ON

Camera MIC Gain

CH1 60dB Local

CH2 60dB Local

1

2

3

* AT Diag *

System Frequency 1.001

Ref.H Phase SD Local

HD-SD DLY 90H

Ret Setting Local

Marker Setting Local

WFM Mode HD ANA

CCU Mode Normal

1
2
3
4
5
6
7

1-12. Character Display Function