Applications, Using the pl 2404 as a recording mixer, Applications notes 23 – Samson PL2404 User Manual

Page 25: Using the pl 2404 as a recording mixer 23, Servo - 240, Risk of electric shock do not open, Cassette or dat, Signal processor, Samson

Advertising
background image

23

Applications

Here are four suggested applications for the PL 2404; bear in mind that your particular circumstance may dictate
changes in these suggested signal connections and routings.

Application 1 - Using The PL 2404 As A Recording Mixer

The PL 2404 is optimized for use as a recording mixer with multitrack digital or analog recorders. As shown in the
illustration below, microphones and line level signals are connected to various channel inputs. Signal processors are
connected to Aux sends and returns and to channel inserts as required. The Control Room outputs are connected to a
power amplifier driving studio monitors. The Main outputs are connected to the inputs of a two-track or DAT recorder,
with the outputs of the two-track or DAT recorder connected to a PL 2404 stereo channel. The four Bus outputs are
connected to the inputs of a multitrack recorder, with the multitrack outputs connected to two PL 2404 stereo channels.
During mixdown, those channels carrying the multitrack outputs are routed to bus 1/2 (via their channel “Mute 3/4”
switches), with buses 1 and 2 routed to the Main L/R outputs (by pressing in their Bus “L/R” switches). To listen back to
the mix, the channel carrying the two-track outputs is routed to bus 3/4 (via its channel “Mute 3/4” switch); then simply
connect buses 3 and 4 to the Control Room outputs by pressing in their Bus “L/R” switches.

CASSETTE or DAT

+15db

0

-15db

0

+15db

-15db

-15db

+15db

0

+15db

-15db

0

SAMSON

SIGNAL PROCESSOR

SIGNAL PROCESSOR

SERVO - 240

SAMSON

L

R

MIDI KEYBOARD

L

R

DRUM MACHINE

MIDI TONE GENERATOR

L

R

MULTITRACK

Ring

Tip

PL 2404 24 CHANNEL PROGRAM STEREO / LINE MIXER

SAMSON

3

1

2

4

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

BUS OUTPUTS
UNBALANCED

<75

Ω+4dBu

R

CONTROL ROOM

BALANCED <75

Ω+4dBu

LINE INPUTS - BALANCED 10K

Ω+4dBu

S/N

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

!

115V - 60 Hz 25W

POWER
RATING

AVIS:

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

MAIN

BALANCED <75

Ω+4dBu

LEFT / MONO

RIGHT

1

2

3

4

1

2

3

4

1

2

3

4

BUS INSERTS

UNBALANCED <75

Ω +4dBu

MIXER LINKING

AUX SENDS

UNBALANCED <75

Ω +4dBu

AUX RETURNS

STEREO INPUTS

UNBALANCED 10K

Ω+4dBu

1

2

3

4

INSERT

L

1

2

3

MIC 1

1

2

3

MIC 3

ON

OFF

~AC INPUT
115V, 60Hz

25W

TRS

STEREO INPUT

TIP = LEFT

RING = RIGHT

SLEEVE = COM

TRS

BALANCED

TIP = HI

RING = LO

SLEEVE = COM

TRS INSERT

UNBALANCED

TIP = RETURN

RING = SEND

SLEEVE = COM

XLR

BALANCED

3 = LO

2 = HI

1 = COM

+4

-10

0

−50

+4

-10

0

−50

POWER

FUSE

1A/250V

R

L

Advertising