Figure 3-2 way to change pwm duty cycle, Figure 3-2, Shows the – Samsung S3F84A5 User Manual

Page 14: Samsung confidential

Advertising
background image

S3F84P4_AN_REV0.00 (PRELIMINARY SPEC)

3 SOFTWARE IMPLEMENTATION

N

Y

Decrease PWM duty cycle

Start

PWMEX>=100B?

PWMEX = 0xFF
PWMDATA - =1

End

PWMEX - =1

N

Y

Increase PWM duty cycle

Start

PWMEX>=

11111100B?

PWMEX + = 1

End

PWMEX = 0

PWMDATA + =1

Figure 3-2 Way to change PWM duty cycle

 Change rate of PWM duty cycle: If PWM in S3F84P4 is 6+6 type, the PWM basic frequency is 6-bit, that

is,

6

8

125

2

64

PWM

f

MHz

KHz

8

PWM

f

MHz

when

. The overall cycle is still 12-bit to make the 12-bit

resolution fully valid, that is,

12

2

PWM

ms

4096

0.512

8

f

MHz

. So Therefore, every change of the duty cycle will

take effect after 0.512ms. Considering the AD conversion duration is 25us, duty cycle can be updated every
21 times of AD conversion.