Storage, Warning, Lubrication check / lubricate free-hand linkage – Snapper E175246E User Manual

Page 20: Lubricating the auger shaft & assembly

Advertising
background image

Storage

LUBRICATION CHECK / LUBRICATE
FREE-HAND LINKAGE

Check the function of the Free-Hand controls: the con-
trols should function as described in the CONTROLS
section. It is critical for the safe operation of the unit
that the controls disengage when released.

If the controls do not function properly, lubricate them. If
lubrication does not rectify the problem, see your dealer.
Under no circumstances should the unit be used if the
controls are not functioning properly.

Figure 15. Lubricate Free Hand Control

STORAGE

Before you store your unit for the off-season, read the
Maintenance and Storage instructions in the Safety
Rules section, then perform the following steps:

• Remove the key.

• Perform engine maintenance and storage measures

listed in the engine owner’s manual. This includes
draining the fuel system, or adding stabilizer to the
fuel (do not store a fueled unit in an enclosed struc-
ture - see warning).

WARNING

Never store the unit (with fuel) in an enclosed,
poorly ventilated structure. Fuel vapors can
travel to an ignition source (such as a furnace,
water heater, etc.) and cause an explosion.

Fuel vapor is also toxic to humans and animals.

Figure 16. Checking Auger Gear Case Lubrication
A. Grease Fittings

C. Cotter Pins

B. Shear Pins

D. Auger Assembly

A

B

D

C

LUBRICATING THE AUGER SHAFT &
ASSEMBLY

1. Remove cotter pin (C, Figure 16) and shear pin (B).

2. Use a grease gun and squirt several shots of grease

into grease fitting (A).

3. Rotate auger assembly (D) several times to distribute

the grease evenly. Repeat step 2.

4. Reinstall shear pin (B) and cotter pin (C).

5. Repeat procedure for other side.

A

B

D

C

IMPORTANT NOTE

It is very important that grease fittings on the auger shaft
are lubricated regularly. If auger rusts to shaft, damage to
worm gear may occur if shear pins do not break.

Before starting the unit after it has been stored:

• Check all fluid levels. Check all maintenance items.

• Perform all recommended checks and procedures

found in the engine owner’s manual.

• Allow the engine to warm up for several minutes

before use.