6

5

7

A. Connect the red wire

through a 1/2-amp fuse
(not supplied), to the
positive DC source.

B. Connect the white wire

from the red LED to one
of the white wires on the
Float Switch Assembly.

C. Connect the remaining

white wire from the Float
Switch Assembly to the
negative DC source.

Place the Switch Assembly into the tank with the

gasket in place. Drive four No. 8 x 3/4” mounting
screws using care to tighten evenly. DO NOT
OVER-TIGHTEN.

Mount the Indicator Assembly. Fasten with the two

No.4 x 1/2” screws provided.

600340507 4/03

Following the wiring diagram, route wires on a

12VDC circuit using good electrical practice.

SPECIFICATIONS

MODEL INFORMATION

Part Number

Description

313000312

TankWatch 1 Panel, Float Assembly

Average Current Consumption: 0.016 amps

Dometic Corporation • Sanitation Systems

13128 State Rt. 226, P.O. Box 38

Big Prairie, OH 44611-0038 USA

330-496-3211

1-800-321-9886 • Fax: 330-496-3097

® Registered; ™ Trademark of Dometic Corporation

© Dometic Corporation