Alarm record setup – Samsung SCR-3000P User Manual

Page 24

Advertising
background image

4-10

4-9

DIGITAL VIDEO RECORDER

4

Alarm Record Setup

The following illustrates the intial setting of the ALARM RECORD SETUP menu.

ALARM SIGNAL DETECTION

You shall select ON to start recording in the event of alarming and select OFF to prevent
recording in the event of alarming. If you set the ALARM SIGNAL DETECTION to ON
and exit the menu, the system will begin recording whenever alarm occurs. To force stop the
recording during the alarm recording, press and hold the STOP( ) button for 3 seconds. Then,
the recording by the current alarm will be stoppted, and the alarm recording will not be per-
formed for the next 5 seconds even if alarm occurs. To completely stop the alarm recording,
go into the menu within that 5 seconds to set the ALARM SIGNAL DETECTION to OFF.
If no action is performed by the user for 5 seconds, the system returns to the alarm recording
mode. [ON/OFF]

ALARM SIGNAL POLARITY

Set to N. C. (Normally Close) when the alarm input is Active High, and set to N.O.(Normally

Open) when the alarm input is Active Low. [N.C./N.O.]

ALARM BUZZER

Set to ON to have the system activate the Buzzer when a motion is deteced in the input
video or when alarm occurs, or set to OFF to keep the Buzzer inactive. [ON/OFF]

MAIN ALARM TIME

Set the duration for which alarm recording is to be performed when a motion is detected in the
input video or when alarm occurs. The value can be set from 0 seconds to 5 minutes when you
set to OFF. If you set to AUTO, the alarm recording is performed only during when the alarm
signal is Active.
[5MINUTE/4MINUTE/3MINUTE/2MINUTE/1MINUTE/30SECOND/20SECOND/

10SECOND/AUTO/OFF]

Note

Note

The following table shows how long it would take to fill up an 80GB HDD for each field
rate.
(Recording time for each field rate may slightly vary depending on the type of input
video singal.)

ALARM RECORD SETUP

ALARM SIGNAL DETECTION

OFF

ALARM SIGNAL POLARITY

N.O.

ALARM BUZZER

ON

MAIN ALARM TIME

10 SECOND

PRE ALARM TIME LIMIT

2 SECOND

POST ALARM TIME LIMIT

OFF

MAIN ALARM PICTURE RATE

30.0 FPS

MOTION DETECTION

OFF

SET AREA & SENSITIVITY

MOVE=[ /

/

/

] SELECT=[ ] EXIT=[MENU]

Time-Lapse Mode

Picture Rate

VERY HIGH

HIGH NORMAL

LOW

80GB

80GB

80GB

80GB

60.0 FPS

11 H

13 H

19 H

25 H

30.0 FPS

22 H

26 H

37 H

49 H

15.0 FPS

44 H

53 H

74 H

99 H

NTSC

10.0 FPS

65 H

79 H

111 H

148 H

7.5 FPS

87 H

106 H

148 H

198 H

5.0 FPS

131 H

159 H

222 H

296 H

2.5 FPS

261 H

317 H

444 H

593 H

1.0 FPS

654 H

794 H

1,111 H

1,481 H

0.5 FPS

1,307 H

1,587H

2,222 H

2,963 H

50.0 FPS

13 H

19 H

27 H

36 H

25.0 FPS

26 H

38 H

53 H

71 H

12.5 FPS

52 H

76 H

107 H

142 H

PAL

8.3 FPS

78 H

114 H

160 H

213 H

6.3 FPS

105 H

152 H

213 H

284 H

5.0 FPS

131 H

190 H

267 H

356 H

2.5 FPS

261 H

381 H

533 H

711 H

1.0 FPS

654 H

952 H

1,333 H

1,778 H

0.5 FPS

1,307 H

1,905 H

2,667 H

3,556 H

Advertising