W1808/W1809/W1810 Cyclone Dust Collectors

SE

T

U

P

14. Attach the outlet port and filter L-braces to the

housing with the outlet gasket between, as shown in

Figures 23 & 24 using the fasteners below.

—Model W1810: Use (10)

5

/

16

"-18 x 1" hex bolts, (20)

5

/

16

" flat washers, and (10)

5

/

16

"-18 hex nuts.

—Model W1809: Use (11)

5

/

16

"-18 x 1" hex bolts, (22)

5

/

16

" flat washers, and (11)

5

/

16

"-18 hex nuts.

—Model W1808: Use (8)

5

/

16

"-18 x 1" hex bolts, (16)

5

/

16

" flat washers, and (8)

5

/

16

"-18 hex nuts.

15. Model W1810 Only: Attach the filter cross braces to

the L-braces, as shown in

Figure 25, using (4)

3

/

8

"-16

x

3

/

4

" hex bolts, (8)

3

/

8

" flat washers, and (4)

3

/

8

"-16

hex nuts.

16. Using the forklift, lift the entire assembly approxi-

mately 2' off the ground to gain clearance for filter

installation.

Figure 23. Attaching the outlet port and

filter L-braces to the blower housing

(Model W1810).

Figure 24. Filter L-braces atttached to

blower housing (Model W1810).

Gasket

Figure 25. Filter cross braces (Model

W1810).

Cross Braces

L-Brace