Ayxp7fr – Sharp AE-X7FR User Manual

Page 11

Advertising
background image

AYXP7FR

3 – 17

Indoor/
outdoor
units in
complete
shutdown

19

-0

Indoor unit fan

Indoor unit fan error

(1)

Check the indoor fan
motor for proper rotating
operation.(Check fan
lock.)

(1)

Replace the indoor fan
motor.

(2)

Check the lead wire of the
indoor fan motor for open-
circuit.

(2)

Replace the indoor fan
motor.

(3)

Check CN1 of the indoor
unit fan motor for secure
installation.

(3)

Correct the installa-
tion of CN1 of the
indoor fan motor.

(4)

No abnormality found in
above inspections (1)
through (3).

(4)

Replace the indoor
unit control PWB.

Indoor/
outdoor
units in
operation

20

-0

Indoor unit con-
trol PCB

EEPROM data error

(EEPROM read data
error)

Replace the indoor
unit control PWB.

Indoor/
outdoor
units in
operation

88

Control and dis-
play PCB

Communication
error

(1)

Check for disconnected
connector between control
PCB and display PCB,
and open-circuit in lead
wires.

(1)

Insert connectors cor-
rectly, or replace con-
trol PWB.

(2)

Check that control PCB
outputs signals correctly.

(2)

Replace control PWB.

Status of

indoor/

outdoor

units

Indication

by LED1

on out-

door unit

*2

Malfunction

No. dis-

played on

main unit

display sec-

tion *1

Content of diagnosis

Inspection location/method

Remedy

Main
cate-

gory

Sub-

cate-

gory

Main category

Sub-category

Advertising
This manual is related to the following products: