CONTROLS & THEIR FUNCTIONS

1. POWER OUTPUT INDICATOR

When lit, this LED indicates that power is available for cutting.

2. ALARM INDICATOR

When lit, this LED indicates that one of the alarms has triggered. At the same time the digital
display (Ref. 3) shows the type of alarm, as shown in the table below, with instructions\for
correcting the problem. In this condition the unit does not supply current.

3. DIGITAL DISPLAY

This display operates in a number of ways:

Display Volts or Amps – by pressing the V/A switch (5), you can read the voltage or amperage at
the torch. This is a momentary display

Display Air Pressure – By pressing the bar switch (6) you can read the operating air pressure of
they system.

Error/Alarm Indications – If an error is present, the display will light showing the code of the error.
The codes are shown below:

DISPLAY

ERROR or PROBLEM

CORRECTION/RESET

- - -

Insufficient input voltage

CUP

The nozzle cap is not properly
screwed on the torch

Turn the unit OFF. Tighten the nozzle
cap on the torch correctly and turn the
unit back ON

HtA

Unit is overheating

Stop cutting – allow the unit to cool down.
Alarm will reset after the unit has cooled
down.

ThA (Flashing)

Unit is approaching
overheating

Stop cutting – allow the unit to cool down.
Alarm will reset after the unit has cooled
down.

Air

Insufficient air pressure

Adjust air regulator to increase pressure.
Check incoming air line.

ScA

Short circuit in output of unit

Turn the unit OFF and turn back ON to
reset

LSF

Arc blow out

Check wear on electrode and nozzle.
Replace if worn. If alarm continues, cycle
the unit off and on.

15