2 burner and nozzle characteristics table, 3 arrangement of burners on cooking hob, Instructions for the installer – Smeg PGF75BE-2 User Manual

Page 12: Burners 1. auxiliary 2. semi rapid 3. ultra rapid

Advertising
background image

Instructions for the installer

30

3.2 Burner and nozzle characteristics table


Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 30/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flow rate

(W)

Flow rate

g/h G30

Flow rate

g/h G31

Auxiliary (1)

1.05

50

30 *

28 **

350

76

75

Semi rapid (2)

1.75

65

33 *

32 **

450

130

128

Ultra Rapid (3)

3.4

94

65 *

63 **

1500

247

243

*/**: diameters marked * and ** must be fitted respectively on valves marked * and
**shown in point "4.1 Adjusting the minimum setting for natural gas".


Burner

Rated

heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flow rate

(W)

Auxiliary (1)

1.05

72

350

Semi rapid (2)

1.75

97

450

Ultra Rapid (3)

3.5

133

1500

3.3 Arrangement of burners on cooking hob

BURNERS

1. Auxiliary
2. Semi rapid
3. Ultra rapid

Advertising