25

R-2397

MAGNETRON REMOVAL

1. Remove the outer case cabinet referring to "OUTER

CASE REMOVAL" and CARRY OUT 3D CHECKS.

2. Remove the eleven (11) screws holding the rear

cabinet to the oven cavity.

3. Disconnect the power supply cord from the noise filter.
4. Remove the one (1) screw holding the earth wire of the

power supply cord to the noise filter angle.

5. Remove the rear cabinet with the power supply cord

from the oven cavity.

6. Remove the two (2) screws holding the magnetron

exhaust duct to upper and lower waveguide.

7. Disconnect all the wire leads from the two (2)

magnetrons.

8. Carefully remove each four (4) screws holding each

two (2) magnetrons to waveguide. When removing
the screws hold the magnetron to prevent it from
falling.

9. Remove the magnetron from the waveguide with care

so the magnetron antenna is not hit by any metal
object around the antenna.

10.Now, the magnetron is free.

CAUTION: WHEN REPLACE THE MAGNETRON,

BE SURE THE R.F. GASKET IS IN PLACE
AND THE MAGNETRON MOUNTING
SCREWS TIGHTENED SECURELY.

1. Remove the outer case cabinet referring to "OUTER

CASE REMOVAL" and CARRY OUT 3D CHECKS.

2. Disconnect the all wire leads from the magnetron(s).
3. Remove the wire holder holding the high voltage

wires.

HIGH VOLTAGE TRANSFORMER REMOVAL

4. Disconnect all wire leads from the high voltage

transformer(s).

5. Remove the each two (2) screws holding each high

voltage transformer.

6. Now, high voltage transformer(s) is (are) free.

BLOWER MOTOR REMOVAL

1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads from the blower motor and

the blower motor thermal cut-out.

3. Remove the one (1) screw holding the blower motor to

the oven cavity.

4. Remove the one (1) screw holding the blower motor to

the chassis support.

5. Remove the blower motor. Now, the blower motor is

free.

STIRRER MOTOR (UPPER) REMOVAL

1. Remove the outer case cabinet referring to "OUTER

CASE REMOVAL" and CARRY OUT 3D CHECKS.

2. Disconnect the wire leads from the stirrer motor (up-

per).

3. Remove the one (1) screw holding the stirrer motor

(upper) to the oven cavity.

4. Turn and lift up the stirrer motor (upper).
5. Now, the stirrer motor (upper) is free.

Oven lamp
socket

Terminal

Wire lead

Flat type small
screw driver

Terminal hole

OVEN LAMP SOCKET REMOVAL

1. CARRY OUT 3D CHECKS.
2. Remove the oven lamp.
3. Pull the wire leads from the oven lamp socket by

pushing the terminal hole of the oven lamp socket with
the flat type small screw driver.

4. Lift up the oven lamp socket.
5. Now, the oven lamp socket is free.

Figure C-1. Oven lamp socket

STIRRER MOTOR (LOWER) REMOVAL

1. Disconnect oven from the power supply.
2. Remove the stirrer motor cover by snipping off the

material in four portions.

3. Where the portions have been snipped off bend the

portions flat. No sharp edge must be evident after
removal of the stirrer cover.

4. Disconnect wire leads from the stirrer motor. (See

"Positive lock connector removal")

5. Remove one (1) screw holding the stirrer motor to

oven cavity.

6. Now, the stirrer motor (lower) is free.
7. After replacement use the one (1) screw to fit the stirrer

motor cover. (This screw has been fitted to the base
plate near the stirrer motor cover beforehand.)

Advertising