ELECTRICAL

110V Operation

When it is necessary to use an extension cord, use the

following guidelines:

• Use cords rated for Standard Service

• Never exceed a length of 100 feet

• Use cords with 16 ga. wire or bigger

• Ensure cord has a ground wire and pin

• Do not use cords in need of repair

Extension Cords

Grounding

This machine must be grounded! The electrical cord sup-

plied with this machine comes with a grounding pin. Do

not remove it. If your outlet does not accommodate a

ground pin, have it replaced by a qualified electrician or

have an appropriate adapter installed.

Note: When using an adapter, the adapter must be

grounded.

The SHOP FOX

®

Model M1036 is prewired for 110 volt

operation. The motor supplied with your new Micro Mill

is rated at 0.2 HP and will draw approximately 2 amps. A

5-15 plug is included for your machine and is intended to

be plugged into a matching 5-15 receptacle.

Connect your machine to a circuit (wire, breaker, plug,

receptacle) that is rated for at least 10 amps.

Keep in mind that a circuit being used by other machines

or tools at the same time will add to the total load

being applied to the circuit. Add up the load ratings

of all machines on the circuit. If the total amp load

exceeds the rating of the circuit breaker or fuse, use a

different circuit.

Figure 2. Typical 110V 3-prong plug and

outlet.

This equipment must be grounded.

Verify that any existing electrical out-

let and circuit you intend to plug into

is actually grounded. If it is not, it will

be necessary to run a separate 12 AWG

copper grounding wire from the outlet

to a known ground. Under no circum-

stances should the grounding pin be

removed from any three-pronged plug

or serious injury may occur.