Preparation - general information, Language setting, Start programming – Siemens IC60 User Manual

Page 2: Clock setting, Detectors, Entry delay time, Exit delay time, Remote control

Advertising
background image

Siemens Building Technologies

Fire Safety & Security Products

01.2008


EN

x

Preparation - General information

Before connecting the battery or switching the main power supply on, unplug the in-

ternal siren for the time of the installation (small plug with cable, directly on the left
lower side of the display).

If the internal buzzer starts beeping: Press

to silence it.

To exit the system at any time: Press and hold the button

.

Reset back to factory setting:

Reset all pins and numbers: Press

200

9

.

Reset all individually changed parameters: Press

200

10

.

Language setting

1. Press

Ctrl

simultaneously

t the “Local Mode” opens.
2. Scroll with the buttons

/

to the posi-

tion “Language” and press

to select.

3. Scroll with the buttons

/

to the lan-

guage you prefer and press

to save.

4. To exit press and hold the button

.

Start programming

Programming the system (steps 2 -10) is
only possible in installer mode. To get into
installer mode the system must be disarmed!

1. Press

user code “147258

t the displays shows: “CLIENT:USER”.
2. Press

installer code “258369

t the displays shows: “ISTALLER:USERS”.

Clock setting

1. Set time: press

26

1

HHMM

2. Set weekday: press

26

2

DAY

(Sunday = 1, Monday = 2…etc.)

3. Set date: press

26

3

DDMMYY

4. Activate automatic daylight saving (default

Europe GMT+1): press

26

4

1

Detectors

Learn the wireless detectors (max.16), be-
fore installing, to the panel. Default settings:
- Zones 1 and 2 are delayed for entry route.
- Zones 3 - 8 are set for normal zones.
- Zones 9 - 16 are set for Stay zones.
We recommend using:
- Zone 1: magnet contact from the entry

door.

- Zone 2: first motion detector for the surveil-

lance of the entry area (control panel).

1. For zone 1: press

164

1

t the keypad will start beeping to indicate

that learn mode has been activated.

2. Press the tamper contact on the detector

or remove the magnet from the door
contact

t it will send a transmission signal. The

panel will confirm if a detector is found
with the message “Found”.

3. Press

to confirm.

4. Repeat actions 1 - 3 to follow up for the

zones 2 - 16 (use the navigation button
to switch to the next zone).

If a detector could not be learned it is either
already learned to the panel, or the transmis-
sion signal was not received - try again.
Already learned detectors can be checked in
“Find Detector” mode: press

166

Entry delay time

The entry delay time is set by default to 20
sec. To change the time (0-9999 seconds)
per zone:

1. Zone 1: press

144

1

seconds

2. Zone 2: press

144

2

seconds

Exit delay time

The exit delay time is set by default to 30
sec. To change the time (0 - 255 seconds)
per area:
Area A: press

60

1

seconds

Remote control

Learn a remote control (max. 16) to the
system starting with user number 21 - 25.
Default setting:

User 21:

ARM User 22:

DISARM

User 23:

STAY

User 25:

FREE

User 24:

(

simultaneously ) PANIC/SOS

1. Remote control 1: press

18

21

Advertising