3. SERVICE ADJUSTMENTS

1. Supply power to the set and measuring instruments and allow to warm up for at least 30 minutes.

NOTE
Be sure to use a non-metallic driver for adjusting there VRs. A metallic driver can cause damage by shorting.

Adjustment tool
1. Digital multi meter
2. Pattern generator
3. Color analyzer

Adjustment mode
Over scan mode

ADJUSTMENT
ITEM

TIMING
PATTERN

SETTING

VR
LOCATION

ADJUSTMENT PROCEDURE

CHECK B+
VOLTAGE

HOLD DOWN
VOLTAGE
SETTING

FOCUS
ADJUSTMENT

HORIZONTAL
PHASE
ADJUSTMENT

VERTICAL
LINEARY
ADJUSTMENT

PINCUSHION
ADJUSTMAN

VERTICAL
CENTER
ADJUSTMENT

VERTICAL
SIZE
ADJUSTMENT

PATTERN GENERATOR
MONOSCOPE PATTERN

PATTERN GENERATOR
MONOSCOPE PATTERN

PATTERN GENERATOR
MONOSCOPE PATTERN

PATTERN GENERATOR
MONOSCOPE PATTERN

PATTERN GENERATOR
MONOSCOPE PATTERN

PATTERN GENERATOR
CROSS HATCH PATTERN

PATTERN GENERATOR
MONOSCOPE PATTERN

PATTERN GENERATOR
MONOSCOPE PATTERN

TEST POINT : D910(-)
DIGITAL VOLT METER
VALUE 46.0

± 0.5 VDC.

TEST POINT : ZD501(-)
DIGITAL VOLT METER
VALUE 8.5

± 0.2 VDC.

Adjusting FBT FOCUS VR to make
csreen corner & center focus be identical.

Adjusting VR401 horizontal phase to
make screen right and left symmetrize.

Adjusting vertical linear control VR302 for
equal spacing of lines between center
extreme of scan.

Adjusting VR304 to make pincushion
distortion be identical.

Adjusting VR303 to make screen up &
down symmetrize.

Adjusting VR301 to make screen V-size
to level wide3/4.

VR503

FBT FOCUS
VR

VR401

VR302

VR304

VR303

VR301

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.

BRIGHT VR ,
CONTRAST VR
and SHARP-
NESS VR TO
MAX.