Legend:
A‘ Adjustable feet

B‘ Water drain (27 mm ø tube)

C‘ Water supply (19 mm ø tube)

D‘ Power mains (13 mm ø power cord)

E‘ Coffee grounds tray

F‘ Single hole to replace holes B’, C’ and D’

(100 mm ø pipe).

fig. 6

A'

D'

C'

F'

B'

A'

A'

A'

E'

fig. 7

Neutral (N) - Blue

Phase (L

1

) - Brown

Phase (L

2

) - Black

Earth - Yellow/Green

Power cord
type H07RNF section 4x2,5 mm

2

fig. 8

Connection of plug

to a 400 V2N~ two-phase mains line

CH

(Switzerland)

CEI

L

1

L

2

N

N

L

2

L

1

Machine surface top

Furthermore it is possible to dispose of the coffee grounds directly
into a container to be placed below the machine surface top, as
follows:
-

drill the surface top as indicated (ref. E’, fig. 6);

-

break the pre-marked diaphragm (ref. E, fig. 6) on the bottom
of the grounds tray (ref. 17, fig. 1).

Important

In order to make connection operations easier, the diameter
of the holes to be drilled in the surface top will have to be
greater than that of the pipes and cables indicated in the
legend of fig. 6.

Danger

According to the norms ruling in the Country where the ma-
chine is installed, the cord for the connection to the mains
must be equipped either by an all-pole switch (with a mini-
mum contacts’ opening clearance of 3 mm), or with a plug
conforming to the norms.

The all-pole switch must be suitable for the power drawn by
the machine and able to detect all voltage polarities.

Check that the electrical cables of the installation are cor-

NB: For the 230V~ single-phase connection it is necessary to use
the special kit (code 1020.R05) and to follow the instructions con-
tained therein.

MACHINE FRONT PART

rectly proportioned to the power drawn by the machine.

The connection point (electrical socket or all-pole switch) must
be placed in a position easily reachable by the user, in order
to be able to disconnect the machine from the mains, should
this be necessary.

In case of installations with 400 V two-phase current, utilise the
phases in such a way as to supply the machine with 230 V single-
phase current (fig. 7).

Only for EUROPEAN models