Adaptation to different types of gas, Replacement of nozzles on the hob, Instructions for the installer – Smeg PGFA95F-1 User Manual

Page 12: 1 replacement of nozzles on the hob

Advertising
background image

Instructions for the installer

4. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.

The cooker hob is set for natural gas NG (2H) at a pressure of 1.0 kPa.
In the case of functioning with other types of gas the burner nozzles
must be changed and the minimum flame adjusted on the gas taps. To
change the nozzles, proceed as described below.

4.1

Replacement of nozzles on the hob

This operation requires no primary air regulation.
1.

Extract the grids and remove all the caps and flame-spreader
crowns;

2.

unscrew the burner nozzles with a 7 mm socket wrench;

3.

replace the nozzles according to the type of gas to be used and the
description in paragraph “4.2 Burner and nozzle characteristics
table”.

4.

Replace the burners in the correct position.

14

Advertising