SECO-LARM USA SD-7103GC-PE User Manual

Enfo rcer sd-7 103gc-pe, Also from seco-larm

Advertising
background image

ENFO

RCER

SD-7

103GC-PE

®

FEATURES

• Lighted push button says “PUSH TO EXIT.”
• Can be easily changed in the field to say “PRESIONE PARA

SALIR.”

• DPST push button rated 5A at 250VAC max.
• Long-life green LED 12/24V AC/DC (Approx. 35,000 hrs.).

CHANGING THE MESSAGE PLATE FROM ENGLISH
TO SPANISH (IF NEEDED)

NOTE - The green translucent switch lens can be taken off for message plate replacement.

This should be done before connecting any wires.

1. If the steel plate is mounted on the wall, it must be taken off the wall first.
2. Disassemble the switch as follows (see fig.2):

a. Pop off the clear plastic protector (A) at the rear of the switch assembly.
b. Unscrew the black plastic nut (B) holding the assembly together.
c. Remove the small black rubber O-ring (C).
d. Separate the switch assembly from the slimline steel plate.

3. Insert the end of a large paper clip or other stiff wire of similar diameter into any of the

four corner holes (D) found at the back of the black switch housing until the green switch
lens (G) pops off.

4. Replace the “PUSH TO EXIT” message plate (F) with the “PRESIONE PARA SALIR” message

plate, or vice-versa. Careful not to lose the rubber seal (E).

5. Snap the lens back on and reassemble the switch and plate assembly.

• Rubber-sealed to prevent liquid penetration in front of

switch.

• Includes six colored, 12-inch wire leads with easy-to-

attach spade lugs for fast installation.

• Includes stainless-steel slimline plate.
• CE and UL approved switch.

Push

-to-E

xit L

ED-Ill

umin

ated

Butt

on w

ith S

limlin

e

Stain

less S

teel P

late

Included in this box:

“PUSH TO EXIT” and “PRESIONE PARA
SALIR” message plates.

Six color-coded, 12-inch, AWG 18 wire
leads with easy-to-attach spade lugs for
fast installation.

Stainless-steel slimline plate.

680-ohm resistor for 24-volt LED
operation.

Connections:

Fig. 1

Fig. 2

SECO-LARM

®

U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606

SECO-LARM's policy is one of continual development and improvement. For this reason,
SECO-LARM reserves the right to change specifications without notice.
Copyright © 2003 SECO-LARM

®

U.S.A., Inc. All rights reserved.

file: SD-7103GC-PEMU.p65

1

15

/

16

(49mm)

4.5” (114mm)

1

1

/

2

(38mm)

15

/

16

(24mm)

11

/

16

(18mm)

1

3

4

2

(+)

(-)

Red wire (LED)
(For 24-volt use included
680-ohm, 0.5 watt resistor.)

Green wire (for N.C.)

Blue wire (for N.O.)

Green wire (for N.C.)

Blue wire (for N.O.)

B - Plastic Nut

C - Rubber O-ring

D - Lens Access Holes

G - Lens

F - Message Plate

A - Plastic Protector

SD-7201GC-PE1

Green Mushroom
Push-to-Exit Plate

Also from SECO-LARM:

SD-7202GC-PE

Push-To-Exit Button with
Switchable English &
Spanish Message Plates

SD-7202BC-HC

“Handicap” Push-To-Exit
Button with
Stainless-Steel Plate

E - Rubber Seal

1

1

1

1

1

1

1

1

1

1

1

1

1

Slim-line
Push-to-Exit Plate

SD-7101KB-PE1

1

7

/

16

(36mm)

Black wire (LED)

INSTALLATION

1. Run four or six wires through the wall to an outlet box:

a. Two wires for 12VDC or 24VDC for the light.
b. Two wires each from the N.O. and/or N.C. terminals of an alarm or access control

system which can unlock an electrically-controlled lock.

2. Connect the included colored wires to the switch (see fig. 1):

a. RED wire to the brass-colored spade connector marked “+”.
b. BLACK wire to the brass-colored spade connector marked “-”.
c. GREEN wires to N.C. connectors marked “1” and “2” (if needed).
d. BLUE wires to N.O. connectors marked “3” and “4” (if needed).

3. Connect the colored wires to wires from the alarm or access control system and the

light’s power source (see fig. 1):
a. RED and BLACK wires - To 12VDC or 24VDC source. For 24VDC operation, connect the

supplied resistor (680-ohm, 0.5 Watt) in line with either the red or black wire.

b. GREEN wires - To the N.C. terminals of the alarm or access control system (if needed).
c. BLUE wires - To the N.O. terminals of the alarm or access control system (if needed).

4. Screw the plate into the back-box, taking care not to crimp the wires.

Advertising