Instructions for the installer – Smeg A11A-6 User Manual

Page 7

Advertising
background image

Instructions for the installer


1

Overhead clearances – (Measurement A)

Range hoods

and exhaust fans shall be installed in accordance with

the manufacturer’s instructions. However, in no case shall the
clearance between the highest part of the

hob

of the cooking

appliance

and a

range hood

be less than 600 mm or, for an overhead

exhaust fan, 750 mm.

Any other downward facing

combustible surface

less than 600 mm

above the highest part of the

hob

shall be protected for the full width

and depth of the cooking surface area in accordance with Clause
5.12.1.2. However, in no case shall this clearance to any surface be
less than 450 mm.


2

Side clearances – (Measurements B & C)
Where B, measured from the periphery of the nearest

burner

to any

vertical

combustible surface

, is less than 200 mm, the surface shall

be protected in accordance with Clause 5.12.1.2 to a height C of not
less than 150 mm above the

hob

for the full dimension (width or

depth) of the cooking surface area. Where the cooking

appliance

is

fitted with a ‘splashback’, protection of the rear wall is not required.


3

Additional requirements for Freestanding and Elevated Cooking
Appliaces – (Measurements D & E)
Where D, the distance from the periphery of the nearest

burner

to a

horizontal

combustible surface

is less than 200 mm, then E shall be

10 mm or more, or the horizontal surface shall be above the

trivet

.

See insets above.

NOTES

1

Requirement 3 does not apply to a freestanding or elevated
cooking appliance which is designed to prevent flames or the
cooking vessels from extending beyond the periphery of the
appliance.

2

The ‘cooking surface area’ is defined as that part of the
appliance where cooking normally takes place and does not
include those parts of the appliance containing control knobs.

3

For definition of hob, see Clause 1.4.64.

4

For definition of trivet, see Clause 1.4.109.

5

Consideration is to be given to window treatments when
located near cooking appliances. See Clause 5.3.4.

9