6. OPERATION

8. OTHER AAA+

TM

ACCESSORIES

The AAA+

TM

control panel can work with different accessories include:

Garage door monitor

TM

sensor, Indoor/outdoor motion sensor, Audio

sensor, Remote control, Audio Alarm, etc. Please visit
www.skylinkhome.com or contact us at [email protected] for
more information of how to fully utilize your Temperature Sensor.

11. WARRANTY

If, within one year from date of purchase, this product should become defective
(except battery), due to faulty workmanship or materials, it will be repaired or
replaced, without charge. Proof of purchase and a Return Authorization are required.

This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.

WARNING:
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.

NOTE:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful inter-
ference to radio communications.

However, there is no guarantee that interference will not occur in a particular
installation. If this equipment dose cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

9. FCC

CUSTOMER SERVICE

17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3
Email:[email protected]
http://www.skylinkhome.com

P/N. 101Z468
US Patent. 6243000B1
©2007 SKYLINK GROUP

If you would like to order Skylink’s products or have difficulty getting them to
work, please :
1. visit our FAQ section at www.skylinkhome.com, or
2. email us at [email protected], or
3. call our toll free at 1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST.

Fax (800) 286-1320

12. CUSTOMER SERVICE

The temperature sensor must be enabled in order to monitor the
temperature and communicate with the control panel. You may enable
the upper temperature limit only, or lower temperature limit only, or both.
To enable the upper or lower temperature limit, simply press “HI” or “LO”.
If the display shows “HI”, that means the upper temperature limit is
enabled. If the display shows “LO”, that means the lower temperature
limit is enabled. If the display shows both “HI” and “LO”, that means both
upper and lower temperature limits are enabled. To disable the tempera-
ture limits, simply press the same button again, until the “HI” or “LO”
doesn’t show up on the display.

External Temperature
If you would like to monitor the external temperature (i.e. outdoor tem-
perature), you may use the external measuring probe. Plug in the external
testing probe as show on the back of the sensor. Ensure to select the
“EXT” on the front panel. If no external measuring probe is plugged in,
but “EXT” is selected, the display will not show any temperature.

External Dry Contact
(Normal Open)
You may connect the temperature
sensor to other devices by the
N/O dry contact. Simply plug in the
cable into the socket on the back
of the sensor as shown. Connect
the other end of the cable to the
device that you would like to con-
nect to. When the temperature is
above or below the preset limits,
the contact will be closed
momentary therefore activating
the connected device.

The maximum ratings of the N/O relay contact is 2A / 24V DC, therefore do
not connect an external device which exceeds this rating. The relay contact
is not designed for AC connection, DO NOT CONNECT AC DEVICE TO THIS
N/O CONTACT.

10. CE

Declaration of Conformity
This equipment complies with the requirements relating to electromagnetic
compatibility, EN 301489-3:2002, EN300220-3:2000. This equipment conforms to
the essential requirement of the Directive (1999/5/EC) of the European Parliament
and of the Council.

7. SENSOR FAILURE OR LOW BATTERY

W hen sensor failure occurs, try the following:

1. Check if the sensor is located at where it should be, and whether there

is any physical damage to the sensor.

2. If the failed sensor is not physically damaged, try to activate the sensor

and see if the control panel reacts to such activation.

3. If not, try to remove the sensor from its location, and bring it closer to

control panel and activate the sensor. It is possible that the sensor is
installed too far from the control panel and it cannot establish a steady
communication with the control panel. If this is the case, please install
the sensor closer to the control panel.

Sensor Low Battery

Two CR-2032 lithium batteries are used to operate the temperature sensor.
When the sensor is in low battery condition, the low battery LED indicator
will be on. Temperature sensor will also send a wireless low battery
signal to the AAA+

TM

Control Panel.

Sensor Failure

The control panel constantly monitors its sensors, if the control panel fails
to communicate with any sensors, it will notify the user by:

1. The zone LED of the failed sensor will be on steadily;
2. Voice announcement “zone X sensor Y failure” will be played.

5. INSTALLATION

The temperature sensor should be mounted onto the wall by 2 screws.
Follow the procedures below:
1. Use a template to mark the location for the 2 screws correctly.
2. Tighten the screws onto the wall half way.
3. Hang the temperature sensor onto the 2 screws.

Note: The temperature sensor is not designed to be used outdoor, it
must be installed indoor. To monitor outdoor temperature, an external
measuring probe can be used, while the temperature sensor is installed
indoor.

When you see the low battery indication,
replace the batteries following the
procedures below:
1) Remove the screw on the back of the

temperature sensor as shown.

2) Rotate the battery compartment, the

batteries can be removed.

3) Place the new batteries into the

compartment, pay attention on the
polarity, as indicated on the diagram.

4) Tighten the screw.

7. SENSOR FAILURE OR LOW BATTERY (CONT)

External
Dry Contact

External
Temperature

Advertising