Senco WARRANTY PC1108 User Manual

Page 10

Advertising
background image

PREPARATION

INITIAL SET-UP:
1. Read safety warnings before setting-up air compressor.
2. Add entire contents of oil from enclosed bottle prior to starting compressor.
3. Ensure the oil level is above the minimum notch and below the maximum notch on the dipstick. If low, add
compressor pump oil.

LOCATION:

CAUTION

In order to avoid damaging the air compressor,do not incline the air compressor
transversely or longitudinally more than 10

°.

1.Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation.
Do not place air compressor in an area:
-where there is evidence of oil or gas leaks.
-where flammable gas vapors or materials may be present.

WARNING
Serious injury or death may occur if electrical sparks from motor and pressure
switch come in contact with flammable vapors, combustible dust, gases or other

combustible materials. When using the air compressor for spray painting, place the air compressor
as far away from the work area as possible,using extra air hoses instead of extension cords.

-where air temperatures fall below 32

°F or exceed 104 °F.

-where extremely dirty air or water could be drawn into the air compressor.

ELECTRICAL:

DANGER

Improper connection of the equipment-grounding conductor can result in a risk
of shock or electrocution. Check with a qualified electrician or service personnel if

you are in doubt as to whether the outlet is properly grounded. Do not use any type of adapter with this
product. If repair or replacement of the cord or plug is necessary,do not connect the grounding wire to
either flat blade terminal. The wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire.

WARNING

This product must be grounded.If there should be a malfunction or breakdown,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock. This product is equipped with a cord having an equipment-

grounding conductor and a grounding type plug. The plug must be plugged into an appropriate outlet
that is properly installed and grounded in accordance with all local codes and ordinances.

1.Senco ® DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power loss and
overheating of the motor. Use of an additional air hose is recommended rather than an extension cord. If use of an
extension cord is unavoidable, it should be plugged into a GFCI found in circuit boxes or protected receptacles. When
using an extension cord,observe the following:

Cable Length

Wire Gauge

Up to 25 feet

12 AWG

Up to 100 feet

10 AWG

Up to 150 feet

8 AWG

Up to 250 feet

6 AWG

Use only 3-blade extension cords that have 3-blade grounding-type plugs and 3-slot cord connectors that will accept the
plug from the product. Use only extension cords having an electrical rating not less than the rating of the product. Do not
use damaged extension cords. Examine extension cord before using and replace if damaged. Do not abuse extension
cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always shut off the air
compressor switch before removing the plug from the receptacle.

10

Advertising