Sony CPD-E220 User Manual

Page 12

Advertising
background image

CPD-E220/E220E/E215E

4-2

A

312 mm

B

MODE

All mode

234 mm

a 1.5 mm
b 1.5 mm

a

B

A

b

B

A

A

0.30 mm

B

MODE

All mode

0.35 mm

Convergence Rough Adjustment

1.

Enter the crosshatch signal.

2.

Recheck focus and readjust when focus was worse.

3.

Adjust roughly H. STAT and V. STAT convergence by 4
pole magnet.

4.

Adjust roughly HMC and VMC by 6 pole magnet.

Convergence Adjustment

1.

Open H and V Stat by 4 pole magnet.

2.

Adjust 6 pole magnet perform HMC and VMC.

3.

Adjust 4 pole magnet close both Stat of R.G.B just overlap
each other Horizontal and Vertical.

4.

Adjust TLH for side MC by TLH magnet when R or B is in
the opposite direction.

5.

Adjust XCV to correct Vertical cross MC.

6.

Adjust XBV to correct Vertical bow MC.

7.

Adjust TLV to corect Vertical tilt MC.

8.

Adjust YCH to correct top and bottom Horizontal cross MC.

9.

Adjust YBH to correct top and bottom Horizontal bow MC.

10. Using permalloys to correct MC of the cornters.
11. Check convergence for whole screen. If necessary, perform

step from 3-9 and correct with permalloys.

12. Paint lock 4 pole magnet, 6 poles magnets, XBV reactor

XCV corrector and TLH corrector handle.

Convergence Specification

White Balance Adjustment Specification

(1) 9300K

(2) 6500K

x = 0.283

±

0.01

x = 0.313

±

0.01

y = 0.298

±

0.01

y = 0.329

±

0.01

(2) 5000K

x = 0.346

±

0.01

y = 0.359

±

0.01

Vertical and Horizontal Position and Size
Specification

Focus adjustment

Adjust the focus volume 1 and 2 for the optimum focus.

XCV

YCH

TLH

TLV

B

R

R

B

R

R

R

B

B

B

B
R

YBH

XBV

R

R

B

B

6Pole Mg

Purity Mg.

DY

CRT

4Pole Mg

Focus 1

(V)

(H)

FBT

Focus 2

YV

XCV

TLH

YCH

Advertising