SATO M5900RVe User Manual

Page 21

Advertising
background image

Unit 3: Installation

SATO M5900RVe Operator Manual

PN 9001125A

Page 3-7

IEEE1284 PARALLEL INTERFACE

The parallel interface is a Plug-In Interface Module that can be installed by the user. It conforms
to the IEEE1284 specification. It will automatically detect the IEEE1284 signals and operate in
the high speed mode. If it does not detect the IEEE1284 signals, it will operate in the standard
Centronics mode, which is significantly slower. For this reason, an interface cable and host
interface conforming to the IEEE1284 specification must be present to fully utilize the speed
capabilities. This interface also operates bi-directionally and can report the status of the printer
back to the host.

SPECIFICATIONS

Printer Connector

AMP 57-40360 DDK (or equivalent)

Cable Connector

AMP 57-30360 DDK (or equivalent)

Cable

IEEE1284 Parallel, 10 ft. (3 m) or less

Signal Level

High = +2.4V to +5.0V, Low = 0V to -0.4V

Data Stream

<ESC>A . . Job#1 . . <ESC>Z<ESC>A . . Job#n . . <ESC>Z

NOTE: Pin assignments begin with one (1) in the upper right corner and
descend to eighteen (18) in the upper left corner. Pin number nineteen (19)
picks up in the lower right corner and descends to thirty-six (36) in the lower
left.

IEEE 1284 PARALLEL INTERFACE PIN ASSIGNMENTS

PIN

SIGNAL

DIRECTION

PIN

SIGNAL

DIRECTION

1

Strobe

To Printer

19

Strobe Return

Reference

2

Data 1

To Printer

20

Data 1 Return

Reference

3

Data 2

To Printer

21

Data 2 Return

Reference

4

Data 3

To Printer

22

Data 3 Return

Reference

5

Data 4

To Printer

23

Data 4 Return

Reference

6

Data 5

To Printer

24

Data 5 Return

Reference

7

Data 6

To Printer

25

Data 6 Return

Reference

8

Data 7

To Printer

26

Data 7 Return

Reference

9

Data 8

To Printer

27

Data 8 Return

Reference

10 ACK

To Host

28

ACK Return

Reference

11 Busy

To Host

29

Busy Return

Reference

12 Ptr Error

To Host

30

PE Return

Reference

13 Select

To Host

31

INIT

From Host

14 AutoFD

1

To Host

32

Fault

To Host

15 Not Used

33

Not Used

16 Logic Gnd

34

Not Used

17 FG

Frame Gnd

35

Not Used

18 +5V (z=24k ohm)

To Host

36

SelectIn

1

From Host

1 Signals required for ieee 1284 mode.